5 INSULATION MEASUREMENT
20
» If the specified value is not reached:
–
Repeat the measurement.
310387-51
–
Clean the sealing surface.
Info
Sealant on the contact surface between the motor
housing and the measurement tip can falsify
measurements.
–
Measure the resistance between the specified points.
Measuring point HV+
–
Measuring point Motor case
Value as per
HV Safety
» If the specified value is not reached:
–
Change the high-voltage wiring harness.
310388-51
–
Measure the resistance between the specified points.
Measuring point HV
− –
Measuring point Motor case
Value as per
HV Safety
» If the specified value is not reached:
–
Change the high-voltage wiring harness.
5.5
Performing an insulation measurement on the stator
Warning
Risk of injury
The measuring points could be live.
–
Use personal protective clothing and comply with the safety measures.
Condition
The KTM PowerPack and motor have been removed.
310389-10
–
Remove screws
1
.