ENGLISH
9
OPERATION INSTRUMENTS
»
Rebound damping of shock absorber
By using the adjusting screw
[1]
, the degree of damping of the rebound can
be adjusted. Turn the knob clockwise to increase damping, turn it counter-
clockwise to reduce damping during rebounding.
STANDARD ADJUSTMENT:
– turn the adjusting screw clockwise to the stop.
– then turn the adjusting screw counterclockwise, counting the number of
clicks that corresponds to the respective type of shock absorber.
WP 12.18.7C.03: 25 clicks
WP 12.18.7C.05: 25 clicks
The damping unit of the shock absorber is filled with high-compression
nitrogen. Never try to take the shock absorber apart or to do any maintenance
work yourself. Severe injuries could be the result.
Never unscrew the screw connection [2] (15mm).
1
2