SERVICE WORK ON THE ENGINE 18
143
S03510-10
Main work
–
Pull the EFI control unit
1
upward off the rubber plugs and
hang to the side.
–
Remove protection cap
2
of the diagnostics connector.
S03511-10
–
Put throttle grip
3
into full throttle position and secure.
S03512-10
–
Plug in wake-up connector
4
for priming the oil pump to the
diagnostics connector
5
.
The combination instrument lighting is activated.
Info
The connector is included as part of the motorcycle's
separate enclosure.
–
Wait for at least five seconds.
–
Release the fixing means from the throttle grip.
The oil pump is timed.
Info
The oil pump is actuated at various speeds.
The procedure is clearly audible.
–
Wait until you can no longer hear the oil pump working.
–
Disconnect the wake-up connector from the diagnostics con-
nector.
Содержание 250 EXC Six Days TPI
Страница 2: ......
Страница 136: ...16 COOLING SYSTEM 134 Finishing work Check the coolant level p 131 ...