15 ELECTRICAL SYSTEM
120
S03489-11
–
Connect positive cable
bk
to the 12-V battery.
Guideline
Screw, battery termi-
nal
M5
2.5 Nm
(1.84 lbf ft)
Info
Contact disk
A
must be mounted under screw
bl
and
cable lug
bm
with the claws toward the battery termi-
nal.
–
Slide positive terminal cover
bn
over the positive terminal.
–
Connect negative cable
bo
to the 12-V battery.
Guideline
Screw, battery termi-
nal
M5
2.5 Nm
(1.84 lbf ft)
Finishing work
–
Mount the seat. (
15.3
Charging the 12-V battery
Warning
Risk of injury
12 V batteries contain harmful substances.
–
Keep 12 V batteries out of the reach of children.
–
Keep sparks and open flames away from 12 V batteries.
–
Only charge 12 V batteries in well-ventilated rooms.
–
Maintain a minimum clearance from inflammable materials when charging 12 V batteries.
Minimum clearance
1 m (3 ft)
–
Do not charge deeply discharged 12 V batteries if the charge is already below the minimum voltage.
Minimum voltage before the start of the charge
9 V
–
Dispose of 12 V batteries with less than the minimum voltage correctly.
Note
Environmental hazard
12 V batteries contain environmentally hazardous materials.
–
Do not dispose of 12 V batteries as household waste.
–
Dispose of 12 V batteries at a collection point for used batteries.
Note
Environmental hazard
Hazardous substances cause environmental damage.
–
Dispose of oils, grease, filters, fuel, cleaning agents, brake fluid, etc., correctly and in compliance with
the applicable regulations.
Содержание 250 EXC Six Days TPI
Страница 2: ......
Страница 136: ...16 COOLING SYSTEM 134 Finishing work Check the coolant level p 131 ...