-97-
The following are device-related private MIB objects:
Private MIB Objects
Set/Get
Value Options
DeviceName.0
Get
KS2260
PortNumber.0
Get
26
F23_Module.0
Get
N/A(0)
FX_Module(1)
F23_Module.0
Get
N/A(0)
FX_Module(1)
G1_Module.0
Get
N/A(0)
TP_10/100/1000T(1)
FX_1000SX_SC(2)
FX_1000SX_LC(3)
FX_1000LX_SC(4)
FX_1000LX_SC(5)
FX_1000LX_SC(6)
FX_1000LX_LC(7)
FX_1000LX_LC(8)
FX_1000LX_S3_SC(9)
FX_1000LX_S5_SC(10)
FX_1000LX_S3_SC(11)
FX_1000LX_S5_SC(12)
G2_Module.0
Get
Same as G1_Module.0
FanStatus1.0
Get
Normal(0)
Warning(1)
FanStatus2.0
Get
Normal(0)
Warning(1)
Refer to MIB file, ks2260-v1.xx.mib for the details. This file can be used
for MIB compiler.
Содержание KS-2260
Страница 117: ... 117 5 5 5 2 Aggregator Information The following pages illustrate three examples No active group configured ...
Страница 118: ... 118 Two Static Trunking groups are configured ...
Страница 119: ... 119 One LACP trunk group is formed Trunking information between Actor and Partner are shown ...
Страница 131: ... 131 5 5 8 Spanning Tree This page shows an example of STP Root Bridge information of the switch ...
Страница 132: ... 132 This page shows an example of STP port status Refer to Chapter 1 for the description of Spanning Tree Protocol ...
Страница 145: ... 145 6 Click Update Firmware in following download complete message to confirm the update 7 Reboot the system ...