background image

>SNMP View Delete <index> 

>SNMP View Lookup [<index>] 

>SNMP Access Add <group_name> <security_model> <security_level> [<read_view_name>] [<write_view_name>] 

>SNMP Access Delete <index> 

>SNMP Access Lookup [<index>] 

 

Using Web Interface 

 

The commands supports configuration for: 

 

-

 

Basic system configuration for SNMP v1 and SNMP v2c 

-

 

Basic system configuration for SNMP v1 trap, SNMP v2c trap and SNMP v3 trap 

-

 

Communities that permit to access to SNMPv3 agent 

-

 

USM (User-based Security Model) user table for SNMPv3 

-

 

VACM (View-based Access Control Model) Viewer table for SNMPv3 

-

 

Group table for SNMPv3 

-

 

Accesses group table for SNMPv3 

 

3.6 SNMP MIBs 

The switch provides the following SNMP MIBs: 

 

-

 

RFC 1213 - MIB II 

-

 

RFC 2674 - QBridge MIB (VLAN MIB) 

-

 

RFC 2819 - RMON (Group 1, 2. 3 & 9) 

-

 

RFC 2863 - Interface Group (IF) MIB 

-

 

RFC 3411 - SNMP Management Frameworks 

-

 

RFC 3414 - User Based Security Model (USM) 

-

 

RFC 3415 - View Based Access Control Model (VACM) 

-

 

RFC 3621 - Power Ethernet MIB 

-

 

RFC 3635 - EtherLike MIB 

-

 

RFC 3636 - 802.3 Medium Attachment Units (MAUs) MIB 

-

 

RFC 4133 - Entity MIB 

-

 

RFC 4188 - Bridge MIB 

-31- 

Содержание KGS-1060

Страница 1: ...KGS 1060 KGS 1060 HP Industrial Managed 10 Port Gigabit Ethernet Switches with 2 Dual speed SFP Slots and 4 PoE PSE Ports Firmware Rev1 05 up User s Manual DOC 150608 1 ...

Страница 2: ...erves the right to revise this documentation and to make changes in content from time to time without obligation on the part of KTI Networks Inc to provide notification of such revision or change For more information contact United States KTI Networks Inc P O BOX 631008 Houston Texas 77263 1008 Phone 713 2663891 Fax 713 2663893 E mail kti ktinet com URL http www ktinet com International Fax 886 2 ...

Страница 3: ...cept any interference received including the interference that may cause undesired operation CE NOTICE Marking by the symbol indicates compliance of this equipment to the EMC directive of the European Community Such marking is indicative that this equipment meets or exceeds the following technical standards EMC Class A EN 61000 6 4 2007 A1 2011 EN 61000 3 2 2006 A1 2009 A2 2009 EN 61000 3 3 2008 E...

Страница 4: ...s 20 2 10 Making Fiber Connection 21 2 11 Making PoE PSE Connections KGS 1060 HP 23 2 12 LED Indication 24 2 13 Making Console Connection 24 3 Manage the Switch 26 3 1 IP Address Password 26 3 2 Configuring IP Address Password via console and telnet 26 3 3 Configuring IP Address via Web Interface 27 3 4 Reference Manuals for Web Console Telnet Management 29 3 5 Configuration for SNMP Management 30...

Страница 5: ...th the following switched ports Eight 10 100 1000Mbps Gigabit copper ports Two dual speed SFP slots for 100Base FX 1000Base X Model Definitions Model Copper ports SFP slots PoE PSE function Power via DC input Powered via PoE capable Software managed KGS 1060 HP 8 2 dual speed 4 PSE ports KGS 1060 8 2 dual speed 5 ...

Страница 6: ...e update MIB file Rev1 05 or up Optical Power Alarm OPA function Auto Laser Shutdown ALS function supported in H W Ver E up Management HTTP HTTPS SSHv2 CLI telnet CLI console SNMP v1 v2c v3 RMON DHCP DHCPv6 client DHCP relay DNS client NTPv4 IPv6 support System Syslog Configuration down upload Software upload Security NAS 802 1X MAC based Web CLI authentication IP MAC binding TACACS IP source guar...

Страница 7: ...1 2 Product Panels The following figure illustrates the front panel and rear panel of the switch KGS 1060 HP Front panel KGS 1060 Front panel 7 ...

Страница 8: ...s Shielded RJ 45 jacks Pin assignments Auto MDI MDI X detection Configuration Auto negotiation or software control Transmission rate 10Mbps 100Mbps 1000Mbps Duplex support Full Half duplex Network cable Cat 5 UTP Dual speed SFP Slots Port 9 Port 10 Compliance IEEE 802 3u 100Base FX IEEE 802 3z 1000Base SX LX mini GBIC Connectors SFP for optional SFP type fiber transceivers Configuration Auto 1000M...

Страница 9: ... 4 Power output pins Positive of power voltage pin 1 2 Negative of power voltage pin 3 6 Standard IEEE 802 3at Classification PD Class 0 4 detection Power Delivery 35W max per port at port output for Cat 5 distance up to 100 meters Protection Under voltage protection Over voltage protection Over current detection Powered via Power over Ethernet KGS 1060 PD Port Port 2 PoE Standard IEEE 802 3af PoE...

Страница 10: ...120VAC 0 5A max Alarm events Power failure Specific port link fault software configured OPA Warning The 48VDC power supply is not supported Mechanical Dimension base 140 x 106 x 42 mm HxDxW Housing Enclosed metal with no fan Mounting Din rail mounting Panel mounting optional Environmental Operating Temperature Typical 30 70 Storage Temperature 40 85 Relative Humidity 5 90 non condensing 60 70 with...

Страница 11: ...occur unplug the product from the electrical outlet and replace the part or contact your trained service provider The power cable extension cable or plug is damaged An object has fallen into the product The product has been exposed to water The product has been dropped or damaged The product does not operate correctly when you follow the operating instructions Do not push any objects into the open...

Страница 12: ...e steps to mount the switch onto a DIN rail are 1 Install the mounting bracket onto the switch unit as shown below 2 Attach bracket to the lower edge of the DIN rail and push the unit upward a little bit until the bracket can clamp on the upper edge of the DIN rail 3 Clamp the unit to the DIN rail and make sure it is mounted securely 12 ...

Страница 13: ...Dimensions 13 ...

Страница 14: ...unting bracket The bracket supports mounting the switch on a plane surface securely The mounting steps are 1 Install the mounting bracket on the switch unit 2 Screw the bracket on the switch unit 3 Screw the switch unit on a panel Three screw locations are shown below 14 ...

Страница 15: ...Dimensions 15 ...

Страница 16: ... power from an external power system Or one can be used to deliver the power received on another to next switch in cascading way Vdc Input specifications Applications Power per PSE port DC working voltage General 7V 60VDC PoE 15 4W max 45V 57VDC Typical 48V High power PoE PoE 35W max 45V 57VDC 52V up for 35W WARNING The 48VDC power supply is not supported Three 2P terminal plugs are provided toget...

Страница 17: ...nput contacts If cascading the power to next switch device is needed install the power wires and plug for another switch Then use another Vdc contacts Note 1 Only up to four device units can be cascaded to receive power from one main power input source 2 The maximal length of the power wire is 1 meter 17 ...

Страница 18: ... AR contacts Alarm Events Input power failure Specific port link down The specific ports can be configured by software OPA alarm if optical power is higher than a upper limit setting or lower than a lower limit setting Relay Logic Normal AR and AR shorted Alarm AR and AR open Note Be sure the voltage applied on AR contacts is within the specification of 30VDC 1A max or 120VAC 0 5A max 2 7 Powered ...

Страница 19: ... diagnostic purpose If any network hanging problem is suspected it is useful to push the button to reset the switch without turning off the power Check whether the network is recovered The button can also be used to restore the software configuration settings to factory default values The operations are Operation Function Press the button and release during switch operation Reset boot up the switc...

Страница 20: ...le for MDI to MDI X connection It simplifies the cable installation Auto negotiation Function The ports are featured with auto negotiation function and full capability to support connection to any Ethernet devices The port performs a negotiation process for the speed and duplex configuration with the connected device automatically when each time a link is being established If the connected device ...

Страница 21: ...ber transceiver into SFP slot the steps are 1 Turn off the power to the switch 2 Insert the SFP fiber transceiver into the SFP slot Normally a bail is provided for every SFP transceiver Hold the bail and make insertion 3 Until the SFP transceiver is seated securely in the slot place the bail in lock position Connecting Fiber Cables LC connectors are commonly equipped on most SFP transceivers Ident...

Страница 22: ...or SFP Port 9 and Port 10 The options are Auto Auto detection for the type of the installed SFP transceiver by reading DDM data 100Mbps transceiver Non auto negotiation forced 100Mbps full duplex 1000Mbps transceiver Auto negotiation 1000Mbps full duplex 100Mbps FDX Non auto negotiation forced 100Mbps full duplex 1Gbps FDX Auto negotiation 1000Mbps full duplex ...

Страница 23: ... pairs 4 5 7 8 of the cable The maximum distance supported is 100 meters 3 The power voltage supplied to the switch must be within the range as specified in section 2 5 to make PoE function working The PSE ports are equipped with the following capabilities 1 Detection for an IEEE 802 3af 802 3at compliant PD 2 No power is supplied to a device which is classified non IEEE 802 3af compliant PD 3 No ...

Страница 24: ...itialization completed with no error Port 1 Port 8 SPEED_LED Port speed status Green ON Speed is 1000Mbps Yellow ON Speed is 10Mbps or 100Mbps BLINK PoE power is on LINK_LED Port link status Green ON Port link is established No traffic Green BLINK Port link is up and there is traffic OFF Port link is down Port 9 Port 10 Speed_LED Port speed link status Green ON A 1000Mbps link is established Yello...

Страница 25: ... 25 Pin Assignments Pin RS 232 signals IN OUT 1 2 7 8 NC 3 RxD IN 6 TxD OUT 4 5 GND Baud Rate information Baud rate 115200 Data bits 8 Parity None Stop bit 1 Flow control None ...

Страница 26: ... the switch 192 168 0 2 255 255 255 0 The switch uses local authentication instead of RADIUS authentication with factory defaults Fixed Username admin Default password No password is required with factory default However the password is used for local authentication in accessing to the switch via console telnet and Http web based interface For security reason it is recommended to change the defaul...

Страница 27: ... user_name Refer to Operation manual for telnet and console management 3 3 Configuring IP Address via Web Interface Start Web Browser Start your browser software and enter the default IP address of the switch unit to which you want to connect The IP address is used as URL for the browser software to search the device URL http 192 168 0 2 Login to Switch Unit When browser software connects to the s...

Страница 28: ...No password is required Click OK to login into the switch Web Page after a Successful Login Select Configuration System IP to configure IP address 28 ...

Страница 29: ... enabled DUT will relay DNS requests to the current configured DNS server on DUT and reply as a DNS resolver to the client device on the network Save Click to save the changes Reset Click to undo any changes made locally and revert to previously saved values Renew Click to renew DHCP This button is only available if DHCP is enabled 3 4 Reference Manuals for Web Console Telnet Management The follow...

Страница 30: ...IPv6 Destination ipv6_addr SNMP Trap Authentication Failure enable disable SNMP Trap Link up enable disable SNMP Trap Inform Mode enable disable SNMP Trap Inform Timeout timeout SNMP Trap Inform Retry Times retries SNMP Trap Probe Security Engine ID enable disable SNMP Trap Security Engine ID engineid SNMP Trap Security Name security_name SNMP Engine ID engineid SNMP Community Add community ip_add...

Страница 31: ...o SNMPv3 agent USM User based Security Model user table for SNMPv3 VACM View based Access Control Model Viewer table for SNMPv3 Group table for SNMPv3 Accesses group table for SNMPv3 3 6 SNMP MIBs The switch provides the following SNMP MIBs RFC 1213 MIB II RFC 2674 QBridge MIB VLAN MIB RFC 2819 RMON Group 1 2 3 9 RFC 2863 Interface Group IF MIB RFC 3411 SNMP Management Frameworks RFC 3414 User Bas...

Страница 32: ...LLDP MIB IEEE 802 1X Port Access Entity PAE MIB TIA 1057 LLDP Media Endpoint Discovery MED MIB IEEE 802 1 Q BRIDGE MIB Private SFPDDM MIB DDM status Private reboot MIB Remote boot over SNMP Private TFTP firmware update MIB TFTP Firmware update via SNMP One product MIB file is also available in the product CD for SNMP manager software ...

Страница 33: ...can support more than one ring connection within a switch It is also able to work with RSTP support concurrently in the switch Some basic information is Supports up to five rings in one switch Supports up to 30 member switches in one ring Provides fast response time than RSTP protocol Works with RSTP protocol concurrently within one switch The following figure illustrates a configuration that thre...

Страница 34: ... same time 4 2 Redundant Ring Applications with industrial standard RSTP protocol It also can be done to support a ring connection using industrial standard RSTP function and establish a backup path In case that any link failure occurs the backup path can link up immediately to recover the network operation 34 ...