background image

(C) 2017 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced in 

any form or by any means or used to make any directive work (such as translation or transformation) 

without permission from KTI Networks Inc. 

 

KTI Networks Inc. reserves the right to revise this documentation and to make changes in content from 

time  to  time  without  obligation  on  the  part  of  KTI  Networks  Inc.  to  provide  notification  of  such 

revision or change. 

 

For more information, contact: 

 

United States

   

KTI Networks Inc. 

 

 

 

 

 

 

P.O. BOX 631008 

 

 

 

 

 

 

Houston, Texas 77263-1008 

 

 

 

 

 

 

 

Phone:  713-2663891 

 

 

 

 

 

 

Fax:   

713-2663893 

 

 

 

 

 

 

E-mail:  [email protected] 

 

 

 

 

 

 

URL:  

http://www.ktinet.com/ 

 

International 

  

Fax:   

886-2-26983873 

 

 

 

 

 

 

E-mail:  [email protected] 

 

 

 

 

 

 

URL:  

http://www.ktinet.com.tw/ 

 

Содержание KC-351 Series

Страница 1: ...1 PoE Powered 10 100BASE TX to 100BASE FX Media Converters KC 351 Series Installation Guide DOC 171215A ...

Страница 2: ...rves the right to revise this documentation and to make changes in content from time to time without obligation on the part of KTI Networks Inc to provide notification of such revision or change For more information contact United States KTI Networks Inc P O BOX 631008 Houston Texas 77263 1008 Phone 713 2663891 Fax 713 2663893 E mail kti ktinet com URL http www ktinet com International Fax 886 2 2...

Страница 3: ... device may not cause harmful interference and 2 this device must accept any interference received including the interference that may cause CE NOTICE Marking by the symbol indicates compliance of this equipment to the EMC directive of the European Community Such marking is indicative that this equipment meets or exceeds the following technical standards EMC Class B EN 61000 6 3 EN55022 EN61000 3 ...

Страница 4: ...6 Loop Back Test Function 13 2 Installation 14 2 1 Unpacking 14 2 2 Safety Cautions 14 2 3 Mounting the Device 15 2 4 Powered by PoE over Cat 5 16 2 5 Powered by External Power Adapter 17 2 6 Making TP Port Connection 18 2 7 Making FX Port Connection 19 2 8 LED Indicators 21 2 9 Performing Loop Back Test 22 3 Optional Configuration Settings 23 3 1 User Inaccessible Jumpers 23 3 1 1 Forwarding Mode...

Страница 5: ...converter ideal for remote areas of a network without AC power outlets 1 1 Key Features Convert speed and media type with full wire speed conversion Support 10Mbps and 100Mbps speed on TP connections Auto negotiation and auto MDI MDI X detection function Link fault pass through function Provide manual configuration settings for TP port to supportconnection to non auto negotiation devices Transpare...

Страница 6: ...tection Signal Compliance IEEE 802 3 10BASE T 802 3u 100BASE TX Data Speed 10Mbps or 100Mbps Duplex Mode Half duplex or Full duplex Configuration Auto negotiation capable and optional forced manual settings Cable Types 10Mbps Category 3 4 or 5 UTP 100Mbps Category 5 UTP Supported Link Distance Up to 100 meters ...

Страница 7: ... back test User Accessible Settings SW NO SETTING STATE FUNCTION SW1 TP Port Configuration OFF Auto negotiation default ON Forced mode SW2 TP Port Duplex OFF Full duplex default ON Half duplex SW3 TP Port Speed OFF 100Mbps default ON 10Mbps SW4 Link Fault Pass Through OFF Disable default ON Enable SW5 Auto status report OFF Disable default ON Enable Optional Settings User inaccessible JP1 JP3 on b...

Страница 8: ...al is detected OFF No optical signal RTP LINK Remote TP port link ON Link up and no traffic OFF Link fault RTP 100M Remote TP port speed ON 100Mbps OFF 10Mbps RTP FDX RemoteTPportduplex ON Full duplex OFF Half duplex RTP LINK 100M FDX LEDs are also used for loop back test report PoE Power over Ethernet Standard IEEE 802 3af PD Powered Device Power Reception TP port RJ 45 Pin 1 2 3 6 or Pin 4 5 7 8...

Страница 9: ...Up to 1522 bytes at store and forward mode No limit at smart forward mode 100to100 Flow Control Back pressure for half duplex mode 802 3x pause frame base for full duplex mode Mechanical Dimension 23mm x 72 5mm x 108mm LxWxD Housing Enclosed metal with no fan Mounting Desktop Wall mount Optional Din Rail Weight 212g Environmental Operating Temperature 5o C 50o C Storage Temperature 20o C 80o C Rel...

Страница 10: ...0dBm SL8 SC SMF 1310nm 0 5dBm 36dBm 0dBm SL10 SC SMF 1550nm 0 5dBm 35dBm 0dBm SL12 SC SMF 1550nm 0 5dBm 35dBm 0dBm Single Fiber Bi Di WDM Series X Port Fiber Wavelength Tx Power Rx Sensitivity Rx Max W3520 SC SMF Tx 1310nm 14 8dBm 31dBm 0dBm Rx 1550nm W5320 SC SMF Tx 1550nm 14 8dBm 31dBm 0dBm Rx 1310nm W3540 SC SMF Tx 1310nm 8 0dBm 34dBm 0dBm Rx 1550nm W5340 SC SMF Tx 1550nm 8 0dBm 34dBm 0dBm Rx 1...

Страница 11: ...ice automatically when each time a link is being established 1 4 3 Far End Fault Function The FX port is facilitated with this function which conforms to IEEE 802 3u 100BASE FX specifications When the FX port detects a link failure on its receiving circuitry it will send out an FEFI Far End Fault Indication signal to the remote connected device to indicate a remote fault is detected It also is cap...

Страница 12: ... the TP port will force a link down on the FX port Similarly a link fault detected on the FX port will also force a link down on the TP port As illustrated in the following figure this function allows to pass TP link fault to the remote link partner and makes the converter like a TP cable extender ...

Страница 13: ...t Function As illustrated in the following figure the local MC starts a loop back test by pressing the loop back test button It sends test frames from its FX port to the remote MC The remote MC forwards the received test frames back to local MC from its FX port The local MC verifies the loop back test frames and display the test result on RTP LINK 100M FDX LEDs This function can help installer to ...

Страница 14: ...mponents inside these compartments If any of the following conditions occur unplug the product from the electrical outlet and replace the part or contact your trained service provider The power cable extension cable or plug is damaged An object has fallen into the product The product has been exposed to water The product has been dropped or damaged The product does not operate correctly when you f...

Страница 15: ... objects on the device Wall Mounting The media converter also can be mounted on a wall On bottom of the device wall mounting hole is provided for wall mounting Din rail Mounting For a Din Rail chassis the media converter can support mounting on a Din Rail An optional Din Rail bracket KC 3DR can be purchased separately Consult your dealer for details The following figures show an example after brac...

Страница 16: ...wer supply by a PoE PSE Switched Port The following figure illustrates the converter is powered by the PoE delivered from a remote PoE PSE switch over Cat 5 Note 1 The Cat 5 used can be the standard Cat 5 cable for Ethernet connection 2 Check the power LED on the converter to see whether the power is received on the Cat 5 3 For the compatibility the remote PoE PSE used must be IEEE 802 3af complia...

Страница 17: ...oltage in your area The AC Power Adapter Specifications AC input power AC power voltage of your area Rated input options AC120V 60Hz AC230V 50Hz AC100V 50 60Hz Rated AC240V 50Hz Rated output DC7 5V 500mA min Steps to apply the power to the converters are 1 Connect power adapter DC plug to the DC input jack located on the back of the converter before connecting to the AC outlet 2 To ensure against ...

Страница 18: ... TIA 568 100 ohm STP Link distance Up to 100 meters Configuration Setup To make a proper connection the following configuration settings are recommended TP port link partner SW1 SW2 SW3 Auto negotiation device Off auto Off full duplex Off 100M Fixed 10M half duplex device On forced On half duplex On 10M Fixed 100M half duplex device On forced On half duplex Off 100M Fixed 10M full duplex device On...

Страница 19: ... C SC 1310nm Duplex MMF 2km SL2 SC 1310nm Duplex SMF 20km SL3 SC 1310nm Duplex SMF 30km SL4 SC 1310nm Duplex SMF 40km SL6 SC 1310nm Duplex SMF 60km SL8 SC 1310nm Duplex SMF 80km SL10 SC 1550nm Duplex SMF 100km SL12 SC 1550nm Duplex SMF 120km Duplex Fiber CWDM Series X Connector Wavelength Fiber Ref Distance CxxW40 SC Tx 1xx0nm SMF 40km Rx 1100 1650nm CxxW80 SC TX 1xx0nm SMF 80km RX 1100 1650nm Tx ...

Страница 20: ...20km Rx 1310nm W3540 Bi Di SC Tx 1310nm Single SMF 40km Rx 1550nm W5340 Bi Di SC Tx 1550nm Single SMF 40km Rx 1310nm Since the WDM single fiber media converters use different wavelengths for transmission and receiving respectively the link partner device located on the remote end of the single fiber should match the wavelength used on the single fiber converter ...

Страница 21: ...nk fault Blink Rx Tx activities FX OL FX port optical link On Optical signal is detected Off No optical signal is detected Link Fault Pass Through Function is enabled TP LINK FX LINK FX OL Interpretation On On On Both TP and FX ports link up Off Off On 1 TP port link fault or 2 FX port received FEFI signal FX port Tx path failed Off Off Off 1 TP port link fault or 2 FX port Rx link failure detecte...

Страница 22: ... It is ON to indicate a complete of loop back test and OFF during test 4 Check RTP FDX LED for the test result It is ON to indicate a TEST PASS and OFF for TEST FAIL 5 Release Loop back test button RTP LINK 100M FDX LEDs are back to display remote TP port status Summary of Loop Back Test LEDs LED Status Interpretation RTPLINK Blink The MC is on Loop Back Test mode RTP100M On Loop back test complet...

Страница 23: ...umpers The setting jumpers are not accessible by users generally For accessing these jumpers the upper case must be removed from the product Removing case must perform by an authorized and experienced technical person The setting jumper block is located on the position shown below The setting functions are as follows JP1 Forwarding mode setting Open Store and forward mode Short Smart forward mode ...

Страница 24: ... same speed on both TP port and FX port Direct conversion method converts the signal between TP port and FX port without storing the received packet on one port then forwarding to another port The media converter operates with the minimum latency Note 1 In direct conversion be sure both devices connected to the TP port and FX port have same duplex mode for proper transmission 2 In direct conversio...

Страница 25: ... method uses pause frames for one port to stop further transmission from its link partner 3 1 3 FX Duplex Setting JP3 This setting is used to set the duplex mode of the FX port 3 2 JP1 JP3 Factory Default Settings The factory default settings for JP1 JP2 and JP3 are as follows JP1 Open Store and forward mode JP2 Open 802 3x function is enabled JP3 Open FX port full duplex ...

Отзывы: