KT-Elektronik ZPR-D Скачать руководство пользователя страница 2

Quick installation and operating manual

KT-Elektronik

Warranty

We permanently enhance our products, therefore we reserve the right to make changes to our products at any 
time and without prior notice.
We take no responsibility for the accuracy or completeness of this manual. No liability can be accepted for the  
use of our products for a buyer specific purpose. Buyer claims, especially claims for damages including lost 
profits or other financial losses are excluded. This does not apply if the damage caused by intent or gross 
negligence.   In  case   of   negligent   violations   of   major   contractual   obligations,   our   liability  is   limited   to   the 
foreseeable damage 

Security advices

Only qualified personnel that is familiar with installation and commissioning of this product 
is allowed to mount and put into operation the device. Appropriate shipping and storage 
are assumed.

The   product   is   designated   for   use   in   heavy   current   equipment.   Installation   and 
maintenance have to be performed according to the corresponding safety regulations.

Content

Commissioning..........................................................................................................................................

3

Mounting.............................................................................................................................................

3

Electrical connection ..........................................................................................................................

3

Operating..................................................................................................................................................

4

Display .....................................................................................................................................................

4

System variants.........................................................................................................................................

5

System variant 1: Solar thermal system.............................................................................................

5

System variant 2: Storage tank heat exchanger................................................................................

6

System variant 3: Raise return flow....................................................................................................

6

System variant 4: Charging pump control I........................................................................................

6

Technical specifications............................................................................................................................

7

Application

The digital solar thermal controller ZPR-D is a universally applicable and robust device for the temperature difference control 
for the area of the solar thermal systems, heating systems and air conditioning systems.
The  device distinguishes  itself by  special  economic  efficiency  and is  held consciously  extremely  easy  in service  and 
assembly. The technical implementation of the solar thermal controller ZPR-D considers in special way the demands of the  
building automation.
These short instructions should deliver with assembly and introduction of the device necessary information. 
Further information is retrievable under http://www.kt-elektronik.de.

2

KA_11986_ZPR-D_EN002

Содержание ZPR-D

Страница 1: ...Solar thermal controller ZPR D Quick installation and operating manual Firmware version 1 0x Mai 2011...

Страница 2: ...heavy current equipment Installation and maintenance have to be performed according to the corresponding safety regulations Content Commissioning 3 Mounting 3 Electrical connection 3 Operating 4 Displ...

Страница 3: ...ing time and minimum idle time is considered A two digit announcement serves the representation of the sensor temperatures and status information Commissioning Mounting The digital solar thermal contr...

Страница 4: ...s switched off in rotary switch position off permanently Anzeige With a green LED right hand the working condition of the ZPR D is indicated Mistake states are shown with sparkling in different mark s...

Страница 5: ...ollector temperature of 130 C with a hysteresis by 20 K Actual pump running idle time The solar pump CP1 is switched on by presentation of the thermal switch condition described on top on at least 1 m...

Страница 6: ...routes the heating circiut return flow about the storage tank if the storage tank temperature SF1 is higher around the adjusted temperature threshold lower rotary switch than the heating circiut retur...

Страница 7: ...d shipping Type of protection IP 40 according to IEC 529 Protection class II according to VDE 0106 Pollution degree 2 according to VDE 0110 Overvoltage category II according to VDE 0110 Humidity class...

Страница 8: ...KT Elektronik GmbH Berlinickestrasse 11 12165 Berlin Telefon 030 79 08 05 0 Telefax 030 79 08 05 20 e mail info kt elektronik de Internet http www kt elektronik de KA_11986_ZPR D_EN002 05 2011...