Installation and Operation Manual

                                                                                                         

20

 

If there is long time button press happened when the display stays 
in some page, then this page of display will be locked. In the same 
way,  long time button press can make a page of display switch 
between lock and unlock status. The LCD display will return to the 
first page “Power & Etotal” automatically if there is no any button 
press operation for a long time and the LCD is not in lock status.

 

“Auto Test Set” display page will only be shown when the inverter 
is set to “Italy” mode.

 

3.    Setting Mode Display

 

The  inverter  could  enter  the  setting  mode  by  long  time  button  press 
when  the  inverter  is  running  in  fault  mode, such  as  the  main  grid 
is not connected to the inverter. The long time button press can make 
the  display  return  to  the  upper  level  menu  or  exit  the  setting 
mode  ,when  the  cursor  point  to  the  title  of  a  page(top  line  of  the 
page).

 

● 

Setting Main Menu

 

 
 
 
 
 
 
 
 
 

● 

Grid Specification Setting Sub Menu

 

 
 
 
 
 
 
 
 
 
 
 
 
 

Setting Option

 

→1.Grid SPEC

 

2.COMM Address

 

 

Short  time  button  press  move 
the  cursor,  and  long  time 
button  press  enter  the  sub 
menu.

 

 

S h o r t  t i m e  b u t t o n  p r e s s move 
the cursor, and long time  button 
press  select  this

 

item “■” indicate 

the  item is selected currently.

 

Grid SPEC

 

1.

China

 

2.

Germany

 

3.

Australia

 

Grid SPEC

 

4.

Italy

 

5.

Spain

 

6.

U.K.

 

Содержание KSG-1.5K-SM

Страница 1: ...201603 Ver 1 0 Solar Inverter Solar Inverter User Manual KSG 1K 1 5K 2K 3K SM...

Страница 2: ...Installation 9 5 1 Packing 9 5 2 Installation of Inverter 9 5 3 Installation Location 10 5 4 Installation Procedure 10 5 5 Wiring 12 5 6 Connection Procedure 14 6 Operation of Grid connected Inverter...

Страница 3: ...fed to municipal Electrical Grid This manual contains important safety and operational instructions that must be accurately understood and followed before operating the products Please refer to this...

Страница 4: ...In order to discharge completely from storage capacitance you can t touch the inverter within at least 5 minutes after disconnection 3 Requirement for Grid Connections These inverters are only used fo...

Страница 5: ...ing may cause stop of the inverter Ensure reliable installation and electrical connection When the photovoltaic generator cells are exposed to light even if it is dim the generator supplies DC voltage...

Страница 6: ...cover all shortage or damage due to design production or components But the warranty doesn t cover the followings Beyond warranty period No effective warranty card and product s series number Damage c...

Страница 7: ...connected System Basically Grid connected system is comprised of 4 portions PV array PV inverter AC connection unit and Public Grid connection unit Once PV arrays receive sun shines they will generat...

Страница 8: ...LCD display panel display working status and power efficiency etc information 3 LED and button 2 LED indicates current working status 1 button is used to switch current LCD display information 4 DC Sw...

Страница 9: ...orts Inverters have 2 pairs of DC ports each pair of input ports have positive and negative connector Please identify the positive and negative position by refer to installation section 4 3 Features D...

Страница 10: ...easy for pedestrian to touch but consider easy installation and easy maintenance as well 3 Make sure the inverter should be kept at least 30CM away from other stuff 4 Don t directly expose the inverte...

Страница 11: ...s shown above the tilt angle should be less 15 2 Don t install inverter on forward tilt wall 3 Don t install inverter on horizontal wall 4 Mount the inverter at height same as eyesight for easy operat...

Страница 12: ...ion pipe into the holes then turn the screw into the expansion pipe The distance between nut and wall should be 10mm atleast 3 Hang the inverter onto screws from top to bottom and check both sides and...

Страница 13: ...onnected with monitoring software via a data logger in the form of daisy chain AC Output Connector for AC output they are L N and PE lines Attention 1 The wire connection can only be done after the in...

Страница 14: ...electrical safety laws and regulations are allowed to connect Miniature circuit breakers It is recommended strongly to install circuit breakers or fuses at the DC input and AC output to ensure safe i...

Страница 15: ...r 2 Connection with Solar Array In order to guarantee installation and operation of system safety external manual breaker has to be configured at DC side The selection of breaker should meet basic cur...

Страница 16: ...Installation and Operation Manual 15 XXXXXX XXXXXX XXXXXX XXXXXX 6 Operation of Grid connected Inverter LCD Working LED Error LED Presss button...

Страница 17: ...us faulty status and termination status 1 Normal Working Status There are two modes standby status and running status for this stage Under this mode the system is running in normal status Meanwhile tr...

Страница 18: ...verter will be in stand by status The input voltage is higher than start voltage the inverter will be in self test status After self testing the inverter will be in normal working status the data only...

Страница 19: ...e in termination status All LCD or LED light will be off and no energy from inverter fed to municipal Grid Meanwhile no energy consumption for inverter itself any actions on the keys buttons are inval...

Страница 20: ...sed for page up moving the cursor the long time press is used for locking the screen selecting item setting and returning to upper menu The LCD back lighting will be turned off 180 seconds after the l...

Страница 21: ...de Display The inverter could enter the setting mode by long time button press when the inverter is running in fault mode such as the main grid is not connected to the inverter The long time button pr...

Страница 22: ...D 123 The password is 123 when enter the Grid SPEC menu COMM Address 002 Short time button press setting the number of this bit and long time button press change to next bit Wifi Reset RESET Short tim...

Страница 23: ...Leakage Fault Error 2 Current leakage too high AC Disconnection Error 3 No municipal Grid detected AC Frequency Fault Error 4 AC frequency too high or too low AC Voltage Fault Error 5 AC voltage is o...

Страница 24: ...en the output power is trending to be stable which expresses that the inverter reach its Max power meanwhile maximum power will be received and transferred into AC to feed to municipal electricity Gri...

Страница 25: ...pin definitions of the RS232 RS485 port RS23 RS485 Pin Signal Assignment Signal Assignment 1 N C A T R 2 TxD B T R 3 RxD N C 4 N C N C 5 Common Common 6 N C N C 7 N C N C 8 N C N C 9 N C 7 2 RS485 RS...

Страница 26: ...N function is required on inverter which has been purchased with RS485 port 7 3 Remote control The inverter can realize the remote SHUTDOWN and ON and power limit regulatory function by the associated...

Страница 27: ...inverter and check whether peripheral facility is leakage 2 After elimination of peripheral interference connect to PV array check leakage again if still exists please contact your inverter distributo...

Страница 28: ...igh wait for 2 minutes after alarm occurs and check whether the inverter can be automatically recovered itself 2 If faulty still occurs please contact distributor EEPROM I O fault 1 Restart the equipm...

Страница 29: ...s Max Output Power W 1000 1500 2000 3000 Rated Output Power W 1000 1500 2000 3000 Output Voltage Range Vac Refer to Table 9 2 Max Output Current A 4 5 7 9 14 Rated Output Voltage Vac 220 230 Rated Out...

Страница 30: ...Range Hz Boot wait time S China 187 252 48 50 5 60 Germany 196 262 47 5 51 5 60 Australia 200 262 48 52 60 Italy 184 262 49 7 50 3 60 Spain 196 253 48 50 5 180 U K 184 262 47 52 180 Hungary 198 253 4...

Страница 31: ...ive humidity 4 100 no Condensation Overvoltage category II DC side III AC side In the running process errors such as AC overvoltage AC undervoltage AC overfrequency and AC underfrequency occur the ser...

Отзывы: