10
Filter GTF
10.1 Areas of application
ECOCLEAN® filters are designed to remove particulate matter, aerosols, oil vapours and
odours from non-aggressive compressed air and technical gases. Depending on the speci-
fic application, different validated filter elements can be installed.
VF25
Coarse filter element for separating impurities up to 25 µm particle size
FF5
Pre-filter element for separating coarser dirt concentrations in a solid or
liquid state
MFO
Fine filter element for separating aerosols up to 0.5 mg/m
³
and particulate matter
up to 1 µm particle size
MF1
Fine filter element for separating aerosols up to 0.1 mg/m
³
and particulate matter
up to 0,1 µm particle size
SMA
Ultra-fine filter element for separating aerosols up to 0.01 mg/m
³
and particulate
matter up to 0.01 µm particle size
CA
Activated carbon filter element for separating oil vapours up to 0.003 mg/m
³
DMF
Dust fine filter element for separating particulate matter up to 1 µm particle size
DF1
Dust fine filter element for separating particulate matter up to 0,1 µm particle size
DSF
Dust ultra-fine filter element for separating particulate matter up to 0.01 µm
particle size
VP MFO Vacuum pump protection filter for a filtration of particles, humidity vapour
and aerosols
V MFO Vacuum pump exhaust filter for a filtration of particles and dust up to 1 micron,
oil carry over at 20°C 0,5 mg/m
³
V SMA Vacuum pump exhaust filter for for a filtration of particles and dust up to 0,01
micron, oil carry over at 20°C 0,01 mg/m
³
V CA
Activated carbon element for separation of oil vapour and odours
up to a value of 0,003 mg/m
³
VMS
Medical sterile filter for vacuum devices to protect centralised hospital vacuum
plant installations from liquid, solid and bacterial contamination up to 0,0001%
regarding to BS3928