WARNING
Danger by strong magnetic field
Danger of crushing injuries when pulling out the rotor!
Due to the strong magnetic field the rotor can be suddenly pulled back into its
original position!
Danger of magnetic parts near the rotor being attracted!
▷
The rotor must generally only be removed from the motor housing by
authorised specialist personnel.
▷
Remove any magnetic parts from the vicinity of the rotor.
▷
Keep the assembly area clean.
▷
Keep a safety distance of at least 0.3 m from electronic components.
CAUTION
Strong magnetic field in the rotor area
Interference with magnetic data carriers, electronic devices, components and
instruments!
Uncontrolled magnetic attraction forces between magnetic components, tools or
similar!
▷
Remove any magnetic parts from the vicinity of the rotor.
▷
Keep the assembly area clean.
CAUTION
Danger by strong magnetic field
Negative impact on or damage to electrical devices!
▷
The rotor must generally only be removed from the motor housing by
authorised specialist personnel.
✓
The relevant notes and steps stated have been observed/carried out.
✓
The pump has cooled down to ambient temperature.
✓
A container for collecting the fluid has been positioned underneath the pump
set.
1.
De-energise the pump set (disconnect the motor) and ensure that it cannot be
re-energised unintentionally.
2.
Close the shut-off elements.
3.
Disconnect the discharge and suction nozzles from the piping.
4.
Depending on the pump/motor size, remove the supports from the pump set.
5.
Remove the complete pump set from the piping.