Fluid handled
Concentration
[%]
Max. temperature
[°C]
Fluid handled
Concentration
[%]
Max. temperature
[°C]
Ferric sulphate (II)
5
80
Boiler feed water to VdTÜV1466
–
140
Iron phosphating solution (alkaline phosphating) approx
. 5
70
Cooling water
4)
(without anti-freeze)
–
60
Acetic acid
10
60
Closed circuit cooling water
–
100
Acetic acid
5
60
Open circuit cooling water
–
100
E-coating (water), anaphoresis
–
35
Cooling water pH value > 7.5 (with anti-
freeze)
6)
–
110
E-coating (water), cataphoresis
–
35
Paint-laden water containing residues of wood
paints
–
30
Ethanol
–
60
Paint-laden water containing residues of
plastics paints
–
30
Ethylene glycol
–
100 Paint-laden water containing residues of metal
paints
–
30
Ethylene glycol base anti-freeze, inhibited, closed
system
50
110 Slightly contaminated water
4)
–
60
Tannic acid
20
80
Tap water
–
60
Glycerine
40
80
Clean water
7)
–
60
Potassium hydroxide
5
40
Raw water
4)
–
60
Potassium nitrate, acid-free
5
30
Swimming pool water (fresh water)
4)
–
60
Potassium sulphate, acid-free
3
20
Lake water (fresh water)
–
60
Kerosene (jet fuel)
–
80
Barrier water
–
70
Condensate
5)
–
120 Fresh water
–
60
Condensate, not conditioned
–
120 Dam water
–
60
Conventional paint on solvent basis
10-40
–
Partly desalinated water
–
120
Copper sulphate
5
80
Drinking water
4)
–
60
Magnesium sulphate
10
80
Permeate (osmosis)
–
140
Maleic acid
10
60
Ultrafiltrate = permeate, pure filtrate, solids
content <1 %
–
30
Milk
–
60
Deionised water, free of solids
–
60
Lactic acid
5
60
Fully desalinated water
–
120
Lactic acid
40
60
Hot water (brewery)
–
60
Sodium carbonate
6
60
Water treated to VdTÜV1466
–
140
Sodium hydroxide
5
40
Water with anti-freeze, pH value > 7.5
4) 6)
–
110
Sodium nitrate, acid-free
10
60
Water, waste water, slightly contaminated
water, surface water
–
60
Sodium sulphate, acid-free
5
60
Water, fire-fighting water
–
60
Sodium hydroxide
15-20
20
Water, surface water
–
60
Oils/emulsions
–
–
Water, rainwater, with strainer
–
60
Peanut oil
–
90
Water, raw water
–
60
Corn oil
–
100 Water, drinking water
–
60
Linseed oil
–
60
Tartaric acid
8
40
Rapeseed oil
–
100 Citric acid
25
30
Soybean oil
–
100 Lye for bottle rinsing
–
90
Spare parts
List of spare parts
Description
Ident. No.
Pressure sensor
-1..3 bar 0.6 m cable (red)
01146960
Pressure sensor
-1.0.10 bar 0.6 m cable (blue)
01146961
Description
Ident. No.
Pressure sensor
-1.0.16 bar 0.6 m cable (light grey)
01146962
Pressure sensor
-1..25 bar 0.6 m cable (green)
01146963
Pressure sensor
-1..40 bar 0.6 m cable (black)
01146965
6)
Anti-freeze on ethylene glycol basis with inhibitors. Content: >20 % to 50 % (e.g. Antifrogen N)
7)
No ultra-pure water! Conductivity at 25 °C: < 800 µS/cm, neutral with regard to chemical corrosion
Monitoring
Intelligent Pressure Sensor
6
PumpMeter
Содержание PumpMeter
Страница 1: ...PumpMeter Type Series Booklet ...