Technical data

Single-phase AC motor

Size

P

1

 

[kW]

p

2

I

N

(230 V)

[A]

I

N

400 V

[A]

Mat. No.

[kg]

6 E

0,65

0,40

3,0

-

39300050

9.2

8 E

0,70

0,40

3,2

-

39300051

9.2

12 E

0,80

0,40

3,6

-

39300052

9.2

14 E

0,95

0,70

4,5

-

39300053

11

18 E

1,15

0,70

5,5

-

39300054

11

22 E

1,50

1,20

7,0

-

39300055

13.3

24 E

1,75

1,20

8,0

-

39300056

13.3

Three-phase motor

Size

P

1

 

[kW]

p

2

I

N

(230 V)

[A]

I

N

400 V

[A]

Mat. No.

[kg]

6 D

0,57

0,40

2,0

1,1

39300057

9.2

8 D

0,60

0,40

2,1

1,2

39300058

9.2

12 D

0,70

0,40

2,3

1,3

39300059

9.2

14 D

0,90

0,70

3,1

1,8

39300060

11

18 D

1,00

0,70

3,5

2,0

39300061

11

22 D

1,40

1,10

5,0

2,9

39300062

13.3

24 D

1,60

1,10

5,5

3,2

39300063

13.3

30 D

2,15

1,50

6,3

3,6

39300064

13.3

Characteristic curves

Filtra N; 6, 8, 12, 14, 18, 22, 24, 30; n = 2800 min

⁻¹

2

Q [m

3

/h]

20

10

0

H

[m]

0

3

0

2

0

1

0

Q [l/s]

0

2

4

6

8

10

4

6

8

12

14

16

18

22

Filtra N

8

Filtra N

12

Filtra N

14

Filtra N

18

Filtra N

22

Filtra N

24

Filtra N

30

Filtra N

6

Domestic water supply / swimming pools

Recirculating pump for swimming pool filtering systems

 

 
 

Filtra N

5

Содержание Filtra N

Страница 1: ...Recirculation Pump for Swimming Pool Filter Systems Filtra N Type Series Booklet...

Страница 2: ...rovided herein must neither be distributed copied reproduced edi ted or processed for any other purpose nor otherwise transmitted published or made available to a third party without KSB s express wri...

Страница 3: ...ems 4 Filtra N 4 Main applications 4 Fluids handled 4 Operating data 4 Designation 4 Design details 4 Materials 4 Product benefits 4 Technical data 5 Characteristic curves 5 Filtra N 6 8 12 14 18 22 2...

Страница 4: ...ged open in the mid dle to facilitate cleaning Drive 230 V single phase a c motor protected by a temperature switch with automatic reset Three phase motor 230 400 V Surface cooled Enclosure IP 44 Ther...

Страница 5: ...57 9 2 8 D 0 60 0 40 2 1 1 2 39300058 9 2 12 D 0 70 0 40 2 3 1 3 39300059 9 2 14 D 0 90 0 70 3 1 1 8 39300060 11 18 D 1 00 0 70 3 5 2 0 39300061 11 22 D 1 40 1 10 5 0 2 9 39300062 13 3 24 D 1 60 1 10...

Страница 6: ...12 14 18 512 5 22 24 30 534 Scope of supply Depending on the model the following items are included in the scope of supply Pump set Accessories Required accessories can be purchased from our distribu...

Страница 7: ...837 833 833 4x 900 02 99 9 01 1x 412 01 2x 412 02 1x 412 03 1x 412 04 2x 912 1 837 2x 912 01 832 831 831 99 9 02 5x 412 01 81 23 171 173 Exploded view List of components Part No Description Part No De...

Страница 8: ...2127 5 03 EN 22 10 2012 KSB Aktiengesellschaft 67225 Frankenthal Johann Klein Str 9 67227 Frankenthal Germany Tel 49 6233 86 0 Fax 49 6233 86 3401 www ksb com...

Отзывы: