![KSB Etachrom NC Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/ksb/etachrom-nc/etachrom-nc_installation-and-operating-manual_2006606011.webp)
Never operate the pump set outside the limits stated in the data sheet and on the
name plate.
Prevent impermissible modes of operation at all times.
2.10.1 Marking
The marking on the pump refers to the pump part only.
Example of such marking: II 2 G c TX
Refer to the Temperature Limits table for the temperatures permitted for the
individual pump variants.
An EC manufacturer's declaration is required for the shaft coupling; the shaft
coupling must be marked accordingly.
The motor must be considered separately.
2.10.2 Temperature limits
In normal pump operation, the highest temperatures are to be expected at the
surface of the pump casing, at the shaft seal and in the bearing areas.
The surface temperature at the pump casing corresponds to the temperature of the
fluid handled. If the pump is heated, the operator of the system is responsible for
observing the specified temperature classes and fluid temperature (operating
temperature).
The table below lists the temperature classes and the resulting theoretical
temperature limits of the fluid handled. (A possible temperature rise in the shaft seal
area has already been taken into account).
The temperature class specifies the maximum permissible temperature at the surface
of the pump set during operation. For the permissible operating temperature of the
pump in question refer to the data sheet.
Table 4: Temperature limits
Temperature class to EN 13463-1
Maximum permissible fluid
temperature
T1
Temperature limit of the pump
T2
280
℃
T3
185
℃
T4
120
℃
T5
85
℃
T6
Only after consultation
with the manufacturer
In the following cases, and if ambient temperatures are higher, contact the
manufacturer.
Compliance with temperature class T5 is warranted for the area of the rolling
element bearings based on an ambient temperature of 40°C, assuming that the
pump set is properly serviced and operated and that the surfaces in the bearing area
are freely exposed to the atmosphere.
If temperature class T6 has to be complied with, special measures may have to be
taken with regard to the bearing temperatures.
Misuse, malfunctions or non-compliance with the instructions may result in
substantially higher temperatures.
If the pump is to be operated at a higher temperature, if there is no data sheet or if
the pump is part of a pool of pumps, contact KSB for the maximum permissible
operating temperature.
2.10.3 Monitoring equipment
The pump (set) must only be operated within the limits specified in the data sheet
and on the name plate.
If the system operator cannot warrant compliance with these operating limits,
appropriate monitoring devices must be used.
Check whether monitoring equipment is required to ensure that the pump set
functions properly.
Pump
Shaft coupling
Motor
Temperature class T5
Temperature class T6
2 Safety
Etachrom NC
11 of 62
Содержание Etachrom NC
Страница 1: ...Standardised Pump Etachrom NC Installation Operating Manual ...
Страница 61: ......