6 Commissioning/Start-up/Shutdown
23 of 40
Emporia MB
6.2.3 Maximum operating pressure
CAUTION
Permissible operating pressure exceeded
Damage to connections and seals!
▷
Never exceed the operating pressure specified in the data sheet.
Table 8:
Maximum operating pressure
Size
Maximum permissible operating pressure
[bar]
MB-101
6
MB-152 to MB-751
10
6.2.4 Fluid handled
6.2.4.1 Fluid temperature
CAUTION
Incorrect temperature of the fluid handled
Damage to the pump (set)!
▷
Do not operate the pump (set) outside the specified temperature limits.
Do not operate the pump at temperatures higher than 90 °C.
6.2.4.2 Density of the fluid handled
The pump input power changes in proportion to the density of the fluid handled.
CAUTION
Impermissibly high density of the fluid handled
Motor overload!
▷
Make sure the motor has sufficient power reserves.
6.2.4.3 Abrasive fluids
When the pump handles fluids containing abrasive substances, increased wear of the
hydraulic system and the shaft seal are to be expected. In this case, reduce the
commonly recommended inspection intervals.
6.3 Shutdown/storage/preservation
DANGER
Electrical connection work by unqualified personnel
Danger of death from electric shock!
▷
Always have the electrical connections installed by a trained and qualified
electrician.
▷
Observe regulations IEC 60364.