5 Operation
16 of 34
Deep Lift System
2553.89/04-EN
901.03
897
901.01
59-11
71-14
901.03
594
Fig. 4:
Removing the connection pipe, weights and guide piece
1. Undo fastening screws 901.03. Remove guide piece 897 from support frame 594.
2. Undo fastening screws 901.01. Pull weights 59-11 off connection pipe 71-14.
3. Undo fastening screws 901.03. Remove connection pipe 71-14.
Removing the spring
WARNING
Risk of injury from spring under tension and moving parts
Risk of shearing and crushing injuries!
▷
Prior to removing spring 950, secure hook 59-18 in closed position with a
suitable tool (e.g. rod/manipulator).
59-18
a)
b)
950
900
594
Fig. 5:
Removing the spring a) closed position b) open position
ü
Hook 59-18 with fitted spring 950 is in closed position.
1. Undo the carabine hooks of spring 950 at support frame 594 and at eyebolt 900
of hook 59-18.
ð
This will cause hook 59-18 to swivel down into open position.
Lowering the pump set
DANGER
Persons in the sump
Danger to life from falling parts!
▷
Make sure that nobody is in the sump while the pump is being lowered or
pulled out.
WARNING
Unintentional start-up
Risk of injury by moving parts!
▷
Always make sure the electrical connections (including control cable) are
disconnected before carrying out work on the pump set.
▷
Secure the pump set against unintentional start-up.