KSB DANAIS 150 Скачать руководство пользователя страница 12

12

7.2.3.

Flange gasket

The dimensional compatibily of the flange gasket must be checked to

ensure the connection quality, according to the dimensions defined

hereunder:

7.2.3.1. DANAÏS MT II, TIGHTNESS AREA AT FLANGE FACING

Class 150 / PN 25

Class 150

Size NPS

Wafer

Lug

Flanged

Size NPS

Ø1

Ø2

Ø3

Ø1

Ø2

Ø3

Ø1

Ø2

Ø3

50

2

93

61

73

92.1

61

73

92.1

71

73

65

2

½

117

73

91

104.8

73

91

104.8

84

91

80

3

127

90

106

127

89

106

127

94

106

100

4

157.5 120

128 157.2 114

128 157.2 120

128

125

5

180

141

148 185.7 141

148 185.7 144

148

150

6

216

170

173 215.9 168

173 215.9 167

173

200

8

260

220

226 269.9 220

226 269.9 220

226

250

10

314

273

273 323.8 273

273 323.8 270

273

300

12

362

322

330

381

322

330

381

339

323

350

14

411

354

385 412.8 381

385 412.8 368

373

400

16

470

406

438

470

433

438

470

421

423

450

18

530

462

498 533.4 492

498 533.4 474

487

500

20

572

508

538 584.2 531

538 584.2 518

526

600

24

676

607

640 692.2 637

640 692.2 625

622

700

28

762

672

728

800

710

728

800

705

705

Class 300

Size NPS

Wafer

Lug

Flanged

Size NPS

Ø1

Ø2

Ø3

Ø1

Ø2

Ø3

Ø1

Ø2

Ø3

50

2

93

61

73

92.1

61

73

92.1

71

73

65

2

½

117

73

91

104.8

73

91

104.8

88

91

80

3

127

90

106

127

89

106

127

100

106

100

4

157

114

128 157.2 114

128 157.2 120

128

125

5

185.7 141

148 185.7 141

148 185.7 144

148

150

6

215.9 168

173 215.9 168

173 215.9 167

173

200

8

269.9 220

226 269.9 220

226 269.9 220

226

250

10

323.8 273

273 323.8 273

273 323.8 281

273

300

12

381

327

330

381

327

330

381

324

323

350

14

412.8 382

385 412.8 382

385 412.8 382

373

400

16

470

433

438

470

433

438

470

422

423

450

18

533.4 494

498 533.4 494

498 533.4 489

487

500

20

584.2 536

538 584.2 536

538 584.2 528

526

600

24

692.2 639

640 692.2 639

640 692.2 625

622

7.2.3.2. DANAÏS TBT II, DIMENSIONS OF GASKET FOR

FLANGED BODY (T7)

To ensure proper connection the dimensions of flange gaskets must

be compatible with the dimensions specified below:

*: 45

_

chamfer

RF

DN NPS ØA

+/--0,5

ØF

0/--10

ØJ

PN 20

DN NPS ØA

+/--0,5

ØF

0/--10

ØJ

ASME B16.5 Class 150

or ASME B16.47 Class 150

80

3

94,5

90,5

101

127

100

4

128,5

125

135

157,2

150

6

177

174

185

215,9

200

8

230

228

239

269,9

250

10

278

279

287

323,8

300

12

326

330

339

381

350

14

376,5

377

387

412,8

400

16

426,5

432

439

469,9

450

18

490,5

477

499

533,4

500

20

530,5

528

540

584,2

550

22

581

587

594

641,4

600

24

627

638

647

692,2

650

26

673

679

688

749,3

700

28

707

710

724

800

750

30

760,5

760

774

857

800

32

813

815

826

914

900

36

918

924

930

1022

1000

40

1023

1010

1029

1124

1050

42

1066

1060

1079

1194

1200

48

1184

1205

1219

1359

Содержание DANAIS 150

Страница 1: ...1 Declaration of conformity 2 2 Declaration of incorporation for Partly Completed machinery 4 3 General 5 4 Safety 5 5 Transport and interim storage 6 6 Description of valves 7 7 Installation 10 8 Co...

Страница 2: ...other standards directives ASME B16 34 EN 10213 Suitable for Fluids group 1 and 2 Conformity Assessment Procedure Module H Production site LA ROCHE CHALAIS Name and address of the notified body for o...

Страница 3: ...50 1200 DANA S TBT II Class 150 DN 150 600 Wafer Lug DANA S TBT II Class 150 DN 80 800 Flanged DANA S TBT II Class 150 DN 200 1050 Buttweld Article 33 REACH None of substances included in the candidat...

Страница 4: ...rements of the annex I of the Machine Directive 2006 42 EC are applied and fullfilled 1 1 3 1 1 5 1 2 1 1 3 2 1 3 4 1 3 7 1 3 8 1 3 8 1 1 4 1 1 4 2 1 1 5 1 1 5 2 1 5 3 1 5 4 1 5 7 1 5 8 1 6 1 1 7 2 2...

Страница 5: ...fitter and the operator user to read this manual before installing commissioning the valve Also this manual must always be available at the site where the valve is installed lt is not enough to observ...

Страница 6: ...25 All sizes not authorized All sizes PS 15 bar max All sizes PS 15 bar max All sizes PS 15 bar max DANA S TBT II flanged class 150 All sizes not authorized All sizes PS 15 bar max All sizes PS 15 bar...

Страница 7: ...PS 50 65 80 100 125 150 200 10 16 25 40 Valves for hazardous liquids and gaz group 1 according to table 6 of annex II PED 6 2 Drawings and documents Type Size mm Type series booklet no 50 600 8460 154...

Страница 8: ...14 196 561 3 213 DN 650 1200 144 1 72 3 914 937 144 1 144 2 914 937 72 3 DN 650 1200 144 1 72 3 937 932 DN 50 650 144 1 144 2 937 72 3 932 144 1 72 3 932 Plastomer seat Plastomer seat fire safe DANA S...

Страница 9: ...50 6 Tightening ring 59 52 Trigger 68 4 Foil 72 2 Centring flange 72 3 Tightening flange 81 2 Wire 100 Body 143 Yoke 144 Seat 144 1 Plastomer Metallic seat 144 2 Fire safe seat 160 Cover 176 Bottom 1...

Страница 10: ...he valve bodies 100 when they are installed and operational ATTENTION The sealing faces of the flanges must be clean and undamaged It is mandatory to add gaskets between body and piping flanges To ins...

Страница 11: ...655 205 900 36 858 295 765 252 1000 40 918 298 829 258 1050 42 960 303 902 306 1200 48 1041 309 1019 358 Wafer and Lug type class 300 Size NPS Disc clearance Size NPS e1 e2 e3 e4 50 2 36 9 65 2 49 13...

Страница 12: ...127 100 106 100 4 157 114 128 157 2 114 128 157 2 120 128 125 5 185 7 141 148 185 7 141 148 185 7 144 148 150 6 215 9 168 173 215 9 168 173 215 9 167 173 200 8 269 9 220 226 269 9 220 226 269 9 220 22...

Страница 13: ...0 461 530 5 532 5 PN 10 16 20 25 ASME B16 5 Class 150 JIS 5K 10K 16K 20K 500 20 528 0 562 0 512 581 5 583 5 PN 10 16 20 25 ASME B16 5 Class 150 JIS 5K 10K 16K 20K 550 22 584 0 620 0 556 635 635 PN 10...

Страница 14: ...tal Vertical T7 Flanged connection type One sling on each side 7 4 Recommendations for installation The wafer lug and flanged valves have to be inserted lightly between flanges with flange gaskets Bef...

Страница 15: ...essary the piping system should be flushed with the valves fully open 9 Maintenance Repair 9 1 Safety Instructions Maintenance and repair work may only be carried out by skilled and qualified personne...

Страница 16: ...ken or warped disc Defect due to water hammer Search the reasons Replace Repair the valve Damaged disc corroded disc Repair the valve Replacement of seal Broken shaft twisted shaft Analyse the defect...