9 Trouble-shooting
58 of 62
Calio Pro / Calio Pro Z
1157.820/01-EN
9 Trouble-shooting
WARNING
Improper work to remedy faults
Risk of injury!
▷
For any work performed to remedy faults, observe the relevant information
given in this operating manual and/or in the product literature provided by the
accessories manufacturer.
If problems occur that are not described in the following table, consultation with the
KSB service is required.
A
Pump is running, but does not deliver
B
Pump does not start up or pump running irregularly
C
Pump running but not delivering water.
D
Noises during pump operation
E
Display
Table 30:
Trouble-shooting
Error
value
Possible cause
Remedy
6)
A
▪
See Error messages
(
▪
The
Pump set status
symbol in the
display extinguishes and the green LED
lights up (service mode activated).
▪
Disconnect the power supply. Then re-establish the power
supply.
Check the power supply and fuses.
▪
Disconnect the plug (power cable) or press the control
buttons (+) and (-) simultaneously for 20 seconds until the
Pump set status
symbol lights up again on the display
(service mode deactivated).
B
▪
Impurities in the pump
▪
B
▪
Blockage in the pump
▪
C
▪
Air in the system
▪
Shut-off elements closed
▪
Vent the system and the pump. (
▪
Open the shut-off elements.
D
▪
Power too high
▪
System pressure too low
▪
Air in the system
▪
Pump running dry
▪
Decrease the discharge head setpoint.
▪
Increase the system pressure by filling more water into the
boiler.
▪
Vent the system and the pump. (
▪
E
▪
See Error messages
(
▪
6
Release pump set pressure before attempting to remedy faults on components which are subjected to pressure.