7 Operation
39 of 62
Calio Pro / Calio Pro Z
1157.820/01-EN
7.1.1 Display
When the pump set is in operation, the display is in idle mode. As soon as one of the
control buttons is pressed, the display is activated and shows the discharge head
setpoint. If 5 minutes pass without any settings being made or the control buttons
being pressed, the display will revert to idle mode.
The symbols indicate operating modes, functions and settings. Lit symbols indicate
the active operating mode, function or setting.
+
-
Fig. 17:
Display
Table 15:
Symbols key
Symbol
Description
Unit
m
Discharge head setpoint
▪
Symbol lights up.
▪
Display shows the set discharge head setpoint as a 2-digit
number.
m
Constant-pressure Control operating mode
▪
Symbol lights up when this operating mode is active.
-
Proportional-pressure Control operating mode
▪
Symbol lights up when this operating mode is active.
-
ECO
Dynamic Control operating mode
▪
Symbol lights up when this operating mode is active.
-
Open-loop Control operating mode
▪
Symbol lights up when this operating mode is active.
-
Pump set status
▪
Smooth operation is indicated by the lit symbol and green
LED.
– Pump set running.
▪
A warning is indicated by the lit symbol and orange LED.
– Pump set running.
▪
An alert is indicated by a red LED. The symbol is not lit in
this case.
– Pump set stops.
▪
Stand-by mode is indicated by a green LED. The symbol is
not lit in this case.
– In dual-pump operation (DUAL) one pump set is in
stand-by mode.
-
Dual-pump operation (DUAL)
▪
The symbol lights up when dual-pump mode is active.
– The pump sets are in duty mode or stand-by mode.
-
Error message (e.g. alert 81)
▪
Warning / alerts are indicated by an error code (10 - 90) on
the display.
-