2 Storage

5 of 16

BACnet MS/TP Gateway

2 Storage

If the ambient conditions for storage are met, the accessories will give reliable service
even after a prolonged period of storage. If stored properly, the product will be
protected for a maximum of 12 months.

Table 2: 

Ambient conditions for storage

Ambient condition

Value

Relative humidity

85 % max. (non-condensing)

Ambient temperature

-10 °C to +70 °C

1.

Store the device in dry conditions, if possible in its original packaging.

2.

Store the device in a dry room in which the atmospheric humidity is maintained
at a constant level (as far as this is possible).

3.

Prevent excessive fluctuations in atmospheric humidity.

Содержание BACnet MS/TP

Страница 1: ...BACnet MS TP Gateway For Calio Supplementary Operating Manual...

Страница 2: ...contents provided herein must neither be distributed copied reproduced edited or processed for any other purpose nor otherwise transmitted published or made available to a third party without the man...

Страница 3: ...3 Description 6 3 1 Compatibility 6 3 2 General description 6 3 3 Commissioning 6 3 3 1 Setting jumpers 8 3 3 2 DIL switch 8 3 3 3 Back up battery 8 3 3 4 Error code 9 3 3 5 Technical data 9 4 Related...

Страница 4: ...information contained in the installation operating manual must be observed Table 1 Relevant operating manuals Type series Reference number of the operating installation manual Calio 1157 82 Manufactu...

Страница 5: ...ed for a maximum of 12 months Table 2 Ambient conditions for storage Ambient condition Value Relative humidity 85 max non condensing Ambient temperature 10 C to 70 C 1 Store the device in dry conditio...

Страница 6: ...umber Master node address 1 MS TP baud rate 38400 The default device ID of the gateway used to identify the device on the BACnet network is created based on the sum total of 247000 fixed value and the...

Страница 7: ...voltage Danger to life Only remove the printed circuit board when de energised 1 2 3 5 4 Fig 2 Removed electronics 1 MS TP bus terminator jumper must be terminated at the last station subscriber 2 Mo...

Страница 8: ...0 0 4 0 0 0 1 0 0 0 8 0 0 1 0 0 0 0 16 0 1 0 0 0 0 0 32 1 0 0 0 0 0 0 64 The master node address can be set from 1 to 127 using the DIP switches It may be necessary to activate several switches to obt...

Страница 9: ...mA at 24 V DC Enclosure IP20 Housing design DIN rail assembly Weight Approx 0 1 kg Dimensions W x H x D 18 x 90 x 115 mm Table 5 Object list Type Instance Object name Value Read Write Description AI 1...

Страница 10: ...Error R FP 19200 E 8 1 B 1000 1000 PRG 1 P BASIC Program Running Halted R W KSB Calio adaption c V20150805 HHO uha MV 1 Calio_OpMode Eco Mode Const Pr Propor Pr Boost R W Selecting the operating mode...

Страница 11: ...tion or fault 5 Service terminal terminals 6 Power supply 9 30 V DC A B GND A B G Calio Tx Rx GND Modbus RS485 NC 0 30VDC 9 30VDC B A GND MS TP NO COM NC R O Uin 0 Run External 0 10 V 0 10V COM Alert...

Страница 12: ...oduct BACnet MS TP gateway Serial number range 2018w01 to 2019w52 is in conformity with the provisions of the following Directives as amended from time to time Electromagnetic Compatibility Directive...

Страница 13: ......

Страница 14: ......

Страница 15: ......

Страница 16: ...KSB SE Co KGaA Johann Klein Stra e 9 67227 Frankenthal Germany Tel 49 6233 86 0 www ksb com 1157 87 04 EN...

Отзывы: