KSB APORIS Series Скачать руководство пользователя страница 5

 

 

 

APORIS - 5 

 

 

 

 

 

2 . G e n e r a l 

 

These  operating  instructions  apply  to  KSB  Double  Offset  butterfly 

valves. 

 

Design, manufacturing and testing of the KSB valves are subject to 

a Quality Assurance System according to EN ISO. 

 

For  a  specific  product  configuration  as  an  actuated  valve,  the 

aggregate  can  be  considered  as  a  partly  completed  machine 
according  to  the  machinery  directive  2006/42/EC  and  comply  with 
the requirements of the directive. 

Correct  installation  and  maintenance  or  repair  are  mandatory  to 

ensure trouble free operation of the valves. 

 

The manufacturer cannot be made liable for these valves if operating 

instructions are not being observed. 

 

ATTENTION  

The  valves  must  not  be  operated  outside  the 

permissible  operating  range.  The  limits  are  indicated  on  the  name 
plate or currently applicable type leaflet. The pressure-temperature 
ratings, in particular, must not be exceeded. Operation of the valves 
outside  the  above-mentioned  conditions  may  result  in  overloads 
which may damage the valves. 

 

The type leaflets can be found at 

www.ksb.com

 

– product catalogue. 

 

Nonobservance of this warning may lead to personal injury 
or property damage, e.g.: 

 

-

 

Injury caused by escaping fluids (cold/hot, toxic, 

flammable,  corrosive  or  under  pressure)  -  Incorrect  operation  or 
destruction of the valve. 

 

The descriptions and instructions in this manual refer to the standard 

versions but also apply to the related variants. 

 

These operating instructions do not take into consideration: 

 

-

 

Incidents  which  may  occur  during  installation,  operation  and 
maintenance. 

 

-

 

T

he local safety regulations. lt is the user’s responsibility to ensure 

that these are also observed by the installation staff involved. 

 

For  actuated  valves,  the  specified  connection  parameters  and  the 
installation  and  maintenance  instructions 

including  the  operating 

manual for the actuator 

- must 

be observed. 

 

ATTENTION  

Handling  a  valve  requires  skilled  and  experienced 

personnel. 

 

The personnel in charge of operation, maintenance and installation 

of this valve must be aware of the interaction between the valve and 
the plant. 

 

Operator’s  errors  concerning  the  valve  may  have  serious 

consequences for the entire plant, e.g.: 

 

-

 

fluid may escape 

 

-

 

downtime of the plant/machine 

 

-

 

adverse  effect/reduction/increase  of  the  efficiency/function  of  a 
plant/machine. 

 

For  further  questions  or  in  case  of  damage  to  the  valve,  please 

contact your KSB Sales Office. 

 

For  further  questions  and  supplementary  orders,  especially  when 

ordering  spare  parts,  please  always  state  the  indications  of  the 
marking plate. 

 

The  specifications  (operating  data)  of  the  valves  are  listed  in  the 

technical documentation & type leaflet of the related valve  

 

When returning valves to the manufacturer, please refer to section 
4. 

 

3 . Safety 

 

This manual  contains  basic  instructions to  be complied  with  during 

operation and maintenance. lt is therefore vital for the fitter and the 
operator/user  to  read  this  manual  before  installing/commissioning 

the  valve.  Also,  this  manual  must  always  be  available  at  the  site 
where the valve is installed. 

 

lt  is  not  enough  to  observe  the  general  instructions  listed  in  the 

section  ”safety”,  the  specific  safety  instructions  listed  in  the  other 
sections should also be observed. 

 

3.1 Safety Symbols in these Operating Instructions

 

 

Safety  instructions  put  forth  in  this  instruction  manual,  the 

nonobservance  of  which  would  involve  the  risk  of  personal  injury, 
they are specially marked with the general hazard symbol: 

 

 

 

in  accordance  with  ISO  3864

-

B.3.1.  or 

with the electric voltage warning sign: 

 

 

 

In accordance with ISO 3864

-

B.3.6. 

 

Safety instructions the nonobservance of which would involve hazard 

to the valve and jeopardize its operation have been marked with the 
word 

 

ATTENTION 

 

lnstructions  directly  attached  to  the  valve,  (e.g.  nominal  pressure) 

must be complied with and maintained in a legible condition. 

 

3.2  

Qualification of personnel and training 

 

The  personnel  for  operation,  maintenance,  Inspection  and 

installation must be adequately qualified for the work involved. The 
personnel  responsibility,  competence  and  supervision  must  be 
clearly defined by the user. lf the personnel in question is not already 
in  possession  of  the  required  know-how,  appropriate  training  and 
instructions  must  be  provided.  lf  deemed  necessary,  the 
manufacturer/supplier  will  provide  such  training  and  instructions  at 
the user’s request. In addition, the user is responsible for ensuring 
that the contents of these operating instructions are fully understood 
by the personnel involved. 

 

3.3  

Danger or nonobservance of the safety 
instructions 

 

Nonobservance of the safety instructions may lead to personal injury 

and  danger  for  both  the  environment  and  the  valve  itself. 
Nonobservance of these safety instructions will also for

feit the user’s 

warranty. 

 

Such noncompliance could result in for example: 

 

- failure of essential functions of the valve/plant 

 

- failure of prescribed maintenance and repair practices 

 

- hazard to people by electrical, mechanical or chemical effects 

 

- hazard to the environment due to leakage of hazardous substances 

 

3.4  

Safety Consciousness 

 

The  safety  instructions  contained  in  this  manual,  the  applicable 

national accident prevention regulations and any of the user’s own 
applicable internal work, operation or safety instructions must be fully 
complied with. 

 

3.5  

Safety Instructions for the User/Operator

 

 

Any  hot  or  cold  parts  of  the  valve  (e.g.  body  or  handle  or 
actuator)  that  could  cause  a  hazard  must  be  protected  by 
the user against accidental contact. 

 

 

Leakage of hazardous substance (e.g. flammable, corrosive, 

toxic, hot) must be drained so as to avoid all danger to people or the 
environment. All relevant laws must be observed. 

 

Electrical hazards must be effectively prevented. (For details, please 

refer to the IEC 364 or equivalent national standard and/or local 

 

utility energy supply regulation

 

Содержание APORIS Series

Страница 1: ...Butterfly Valve APORIS DN 300 2000 Epoxy coated Flanged Ends Operating Instructions...

Страница 2: ...ed The contents provided herein must neither be distributed copied reproduced edited or processed for any other purpose nor otherwise transmitted published or made available to a third party without K...

Страница 3: ...Description 2 General 3 Safety 4 Transport and Interim Storage 5 Operating Limits Description of valves 6 Installation 7 Commissioning Decommissioning 8 Maintenance Repair 9 Trouble Shooting 10 KSB Se...

Страница 4: ...er applications to WRAS elastomer and coating Manual actuator gearbox Variants Limit switches PN10 PN25 PN40 pressure class and flanges Pneumatic actuators Electric actuators Locking device Product be...

Страница 5: ...d maintenance lt is therefore vital for the fitter and the operator user to read this manual before installing commissioning the valve Also this manual must always be available at the site where the v...

Страница 6: ...gaged 3 7 Unauthorized Modification and Manufacturing of Spare Parts The equipment shall not be altered or modified in any way prior to consultation with the manufacturer Genuine spare parts and acces...

Страница 7: ...allowable temperature 7 Pipe flange drilling pattern 8 Internal material code 9 Month and year of production 10 Equipment serial number 5 2 Drawings and documents Type DN mm PS bar Leaflet No APORIS...

Страница 8: ...ed at the end of a pipe with a blind flange downstream is not to be considered as an end of pipe service Valves Gas or liquids Liquids Hazardous Group 1 Non hazardous Group 2 Hazardous Group 1 Non haz...

Страница 9: ...t be warning signs fitted showing that it is dangerous to touch these valves lf a valve is used as end valve in a pipe this valve should be protected against unauthorized or unintentional opening to p...

Страница 10: ...checked to ensure the connection quality according to the dimensions defined hereunder Size 1 2 300 369 308 400 479 403 500 608 503 600 719 606 700 793 703 800 900 803 900 1000 903 1000 1111 1003 1200...

Страница 11: ...works Verify that there are not damages caused by the piping cleaning washing process Never suspend the valve by its disc or handle or actuator Verify that all seals and gasket are cleaned and withou...

Страница 12: ...position of the disc is indicated by the pointer of the actuator or by handle lever The valves are closed by turning in the clockwise direction top view and opened in the counter clockwise direction 7...

Страница 13: ...valves or dismantled the energy supply must be shut down prior to starting any repair work Remove the valve from the piping with its actuator Do not damage the liner during removal the valve from the...

Страница 14: ...orable flow and impairment of movement Change installation position Leaks in the body seat Valve not completely closed Close valve completely Valve seal damage or worn Replace seal Cavitation in Valve...

Страница 15: ...f the valve types Butterfly valves APORIS 16 PS 16 bar DN300 2000 As per harmonized standards EN593 EN12266 1 EN12516 2 EN12516 4 And other standards EN1563 Conformity Assessment Procedure Module H PE...

Страница 16: ...APORIS 16 8123 82 04 EN 16 05 2018 KSB S A S 4 all e des Barbanniers 92635 Gennevilliers Cedex France T l 33 1 41 47 75 00 www ksb com...