background image

Amamix

 

-  direct

3

1

Pre - conditions for Installation

1.1

General

-  Safety

This operating manual contains basic instructions, which must be
observed during installation, operation and servicing. Therefore
it is imperative that this manual is read prior to assembly by the
installer  and  relevant  skilled  staff/and  operators,  and  it  must
always be kept within the locality of the machine/plant.

Do not only observe the general safety notes under this section,
but  as  well  any  other  notes  regarding  safety  included  in  the
manual.

-  Marking of Instructions

All safety instructions included in this manual are preceded by the
general hazard symbol, i.e.

The non- observance of this symbol may pose a health hazard to
those attending the site.

Warnings against electrical danger are preceded by this symbol:

The non- observance of this symbol may pose a health hazard to
those attending the site.

All  safety  instructions  in  this  operation  manual,  the
non - observance  of  which may endanger the mixer itself or its
safe operation are preceded by the word

Attention

-  Personnel Qualification and Training

All personnel involved in the operation, maintenance, inspection
or  installation  of  the  mixer  must  be  qualified  for  the  work  in
question.    The  personnel’s    responsibilities,  competence  and
supervision must be clearly defined by the user.  To the extent that
the  personnel  in  question  is  not  already  in  possession  of  the
required  skills  and  know - how,  appropriate  training  and
instructions  must  be  provided  for.    If  required,  the
manufacturer/supplier  will  provide  such  training  at  the  user’s
request. In addition, the user is responsible for ensuring that the
contents  of  the  operation  manual  are  fully  understood  by  the
personnel involved in the work.

-  Dangers Resulting from Non - compliance with the 

 Safety Instructions

Non - compliance with the safety instructions may endanger the
safety of people, property, the environment and the mixer itself.
Non - compliance with the safety instructions will also lead to the
forfeiture of any and all rights to claims for damages.

More specifically, non - compliance may, for example, result in:

-

Failure of essential mixer and/or plant functions;

-

Health hazard due to electrical shock, mechanical impact,
chemical contamination.

-

Pollution of the environment by the leakage of 
hazardous substances.

-  Safety Awareness

It is imperative to comply with the safety instructions contained in
this operation manual, the relevant national accident prevention
regulations and any of the user’s own work, operation and safety
regulations.

-  Safety Instructions for the User / Operator

Take the necessary precautions to preclude all electrical hazards
(for more information, consult the stipulations of the local power
supply companies).

Safety  Instructions  for  Maintenance,  Inspection  and
Installation Work

The  user  is  responsible  for  ensuring  that  all  maintenance,
inspection and installation work is carried out by duly authorized,
adequately  qualified,  specialist  personnel  who  are  thoroughly
familiar with the contents of this operation manual.

As  a  general  rule,  work  on  the  mixer  must  only  be  performed
during  standstill.    The  shutdown  procedure  described  in  the
manual  for  taking  the  machine  out  of  service  must  be  strictly
adhered to.

Mixers  used  to  handle  hazardous  substances  have  to  be
decontaminated.

Immediately following completion of the work, all safety - relevant
and protective devices must be re - installed and/or re- activated.

Please  follow  all  instructions  set  out  in  the  chapter  entitled
“Commissioning”  before  returning  the  machine  to  service
(included in the mixer operating instructions, 1592.87.1 - 14).

-  Unauthorized Modification and Manufacture of Spare 

   Parts

Neither the unit itself nor any installation hardware or accessory
may be modified or altered in any way without the prior consent
of  the  manufacturer.The  use  of  genuine  spare  parts  and
accessories  approved  by  the  manufacturer  helps  ensure  the
operational safety and reliability of the equipment. Please note
that  the  use  of  other  than  genuine  parts  and  approved
accessories  can  invalidate  the  manufacturer’s  liability  for
consequential damage.

1.2

Checking the Site before Installation

Check that the building dimensions are in accordance with the
dimension  sheet.  To  ensure  that  the  carrying  capacity  of  the
foundation is sufficient for installation of the unit, the strength of
the concrete must be at least 3,000 psi. Check that the concrete
foundation has set before proceeding with the installation of the
mixer.

Even if the reservoir floor is inclined, the surface must be leveled
if the installation parts are to be mounted to it securely.

1.3

Checking the Parts Before Installation

Before starting the installation, check that the installation parts
and accessories are complete and that they have not suffered any
transportation damage.

Содержание Amamix

Страница 1: ...instructions concerning the mixer itself or its compo nents This instruction manual contains fundamental information about the installation and operation of the mixer accessories The responsibility fo...

Страница 2: ...the Mixer on the Support Foot 4 3 1 Installing the Mixer on the Reservoir Floor 4 3 2 Fixing the Dead ending the Electrical Power Cable 4 3 3 Commissioning 5 3 4 Installation of Standard Accessories S...

Страница 3: ...fety Awareness It is imperative to comply with the safety instructions contained in this operation manual the relevant national accident prevention regulations and any of the user s own work operation...

Страница 4: ...the mounting bracket and fasten the clamping bolts provisionally While this is done adjust the inlet incidence angle of the mixer relative to the support foot direction of the jet as required Tighten...

Страница 5: ...ply making sure not to chafe the cable if necessary provide some type of cushioning Power Cable Kellum Grips Supplied by others Too loosely laid cables may be damaged by the turbulence of the flow or...

Страница 6: ...lling angle Amamix o 215 G 30o 215 C 300 with motor 1 6 25o 300 with motor 2 6 45o 400 35o Dimension table 1 for mixer preassembled wit h accessories only Size Motor size Dimensions inches Amamix D A...

Страница 7: ...level on the mast tube Move the mast and the inserted base bracket to the position on the tank floor that will insure that the unit is plumb in all directions Line drill and install the anchor bolts i...

Страница 8: ...ied in the mixer operation manual If the propeller is only partly covered by the liquid the bearings will be unevenly loaded the mixer will be subject to increased vibrations and the shaft bearings an...

Страница 9: ...ct 9 NOTE The hHmin dimension is from the bottom of the sump to the center line of the propeller Center support of guide pipe Size hHmin inches 215 4 15 16 300 5 15 16 Amamix 400 9 Amamix 500 12 5 8 6...

Страница 10: ...in bearing part and spherical plain bearing to stop the parts turning around the guide pipe axis horizontally Note For this purpose the adjustment strap has a 30 hole to accommodate the head of the b...

Страница 11: ...1592 821 14 06 2004 Subject to modification without notice KSB INC 4415 SARELLEN ROAD RICHMOND VA 23231 Tel 804 222 1818S Fax 804 226 6961S www ksb inc com Amamix direct...

Отзывы: