5 Installation at Site
35 of 126
Amacan S
1589.837/01-EN
Fig. 23:
Lowering the pump set
25. Progressively lower the pump set into the discharge tube. Secure the cable
bundle with cable clamps.
26. Finally, attach the support rope with shackle and turnbuckle to a suspension
loop (provided in the discharge tube or structure). Secure the turnbuckle with a
split pin. After inserting the split pin, bend over its two legs.
27. Tighten the turnbuckle until the cables are tight but do not lift the pump off its
seat.
28. Unclip the hook of the lifting equipment from the lifting lug, free the electric
cables from the manila rope and route them to the control cabinet.