5 Installation at Site
17 of 36
Calio-Therm NC
1157.881/03-EN
5 Installation at Site
5.1 Safety regulations
DANGER
Installation in potentially explosive atmospheres
Explosion hazard!
▷
Never install the pump in potentially explosive atmospheres.
▷
Observe the information given in the data sheet and on the name plates of the
pump system.
CAUTION
Improper installation of the pump set
Damage to the pump set!
▷
Observe the permissible ambient conditions and the pump set’s type of
enclosure.
▷
Observe the permissible ambient temperatures. Ambient temperatures < 0 °C
are not permitted.
▷
In the event of outdoor installation, fit a protective roof to protect the pump
set from the weather (e. g. sun, rain, snow).
5.2 Checks to be carried out prior to installation
Before beginning with the installation check the following:
▪
The pump set can be operated on the power supply network according to the
data on the name plate.
▪
The fluid to be handled matches the description of suitable fluids.
(
▪
All structural work required has been checked and prepared in accordance with
the dimensions in the outline drawing.
5.3 Installing the pump set
DANGER
Leakage at the pump
Hot fluids escaping!
▷
Fit the sealing elements and make sure they are positioned correctly.
CAUTION
Ingress of fluid into the motor
Damage to the pump set!
▷
Install the pump set with the pump shaft in a horizontal position. Connect the
piping without transmitting any stresses and strains.
▷
Never install the pump set with the motor terminal box pointing downwards.
▷
Undo the hexagon socket head cap screws. Then turn the motor housing.