9
8
SETTINgS ADJUSTMENT
SETTINgS ADJUSTMENT
DETECTION RANgE:
This faucet was supplied with a self
adjusting sensor. The ideal detection range for the specific
location will be set automatically.
Only if necessary, use the remote control to adjust the
sensor range as follows:
Press the RANgE button. wait until a quick flashing of the
LED in the sensor eye is perceived. Then, press + to increase
the range and – to reduce it. Every push will increase or
decrease one level.
Note: Once you have changed the detection range with the remote control,
the distance will be remembered by the sensor, even if the power source is
disconnected. To get back to the self adjustment mode, use the ADJ button only.
Entrance to the self adjustment mode: Check that no
objects are in front of the sensor. Press the ADJ button.
Once a quick flashing of the LED of the sensor eye is
perceived, remove your hand holding the remote control
and move away from the sensor area. The ideal sensor
range for the specific location will be set automatically.
Once the self adjustment has taken place, the solenoid
valve will be opened and closed for 1 second as an
indication that the ideal sensor range was set and the
product is ready for use.
Security time: The Security time, prevents continuous
running of water due to reflections or vandalism. By
default, if the sensor is covered for more than 90 seconds
the water flow will shut automatically. To resume regular
operation any obstruction must be removed.
Press the SEC button. wait until a quick flashing of the LED
in the sensor eye is perceived. Then, press + to increase the
security time and – to reduce it.
DELAY IN TIME: It is recommended to change the delay in
time for flush valves for urinals or toilets only.
If required, the delay in time can also be modified in faucets
as follows:
Press the IN button. wait until a quick flashing of the LED in
the sensor eye is perceived. Then, press + to increase the
delay in time and – to reduce it.
DELAY OuT TIME: This button allows modifying the water
flow time after the user removes his hands from the
faucet. A delay out time close to 0 will save more water.
An increased delay out time will make the user experience
more comfortable.
If required, the delay out time can be modified as follows:
Press the OuT button. wait until a quick flashing of the LED
in the sensor eye is perceived. Then, press + to increase the
delay out time and – to reduce it.
24 HOuR HYgIENE FLuSH: This model includes a 24 hours
hygiene flush which is disabled. To activate the hygiene flush,
press the clock button. wait until a quick flashing of the LED
in the sensor eye is perceived. Then press + to activate the
hygiene flush. To disable it again, press – to deactivate it.
COMFORT FLuSH: If your model includes a Comfort flush
setting, it can be activated by pressing the flush button.
when the button is pressed, one blink of the LED in the
sensor eye is perceived. The pre-programmed flush cycle will
take place then.
The Comfort flush cannot be interrupted or deactivated by
pressing any button until it is over.
TEMPORARY OFF FuNCTION: This function is ideal to
perform any kind of activity in front of the sensor without
operating the system (for example, cleaning).
The faucet will remain shut for 1 minute when this button
is pressed once. To cancel this function and to return to
normal operation press the On/Off button again or wait
1 minute.
RESET BuTTON: This function restores all the factory
settings except for the sensor range. If required, press the
Reset button and without releasing it, press the + button
once.
NOTE: To enter the self adjusting mode, use the ADJ button. To change the
sensor range, use the RANgE button.