![Krystufek PANCONTROL 9120037330077 Скачать руководство пользователя страница 24](http://html.mh-extra.com/html/krystufek/pancontrol-9120037330077/pancontrol-9120037330077_manual_2006359024.webp)
English
24
Group 2
REV
Revolutions total
M
Length (Meter)
In ( Inch), FT (Feet), Yd (Yard)
Reflection marker
Cut off a square of about 12 mm from the reflective tape. (Reflection
Marker)
The shaft surface must be smooth and clean before applying the
reflection marking.
The non-reflective surface of the shaft must be larger than the reflective
surface.
If the shaft is reflective, it must be covered with black tape or paint before
applying the reflective marking.
Measured value memory
Saving data:
Note Chart Fig. 4
1.
Press the MEAS button until the measurement appears in the display.
2.
Observe the measurement and press the MEM button without releasing
MEAS. The maximum, minimum, average, and the current value are
stored in a record. Then the number of the record increases by one.
Retrieving data:
Note Chart Fig. 5
1.
Turn on the device with the MEAS button.
2.
Then press the MEM button several times. The device displays the records
one at a time.
3.
If there is an empty record, OL appears. If there are values, you will see
the maximum, minimum, average, and the last reading one at a time.