background image

Krowne Metal Corporation 

•  100 Haul Rd. Wayne, NJ 07470

P: (800) 631-0442 • F: (973) 872-1129

[email protected] 

krowne.com  

6

Modular Bar Die Installation

Instructions

Install bar counter and removable front millwork panels. It is very important to have the front panels removable to allow access from 
the customers side for plumbing, electrical and beverage lines. Our front panels use interlocking panels and hidden screws meaning 
they make accessing the underside of the bar very easy and the screws cannot be seen by customers making it a much nicer finish.

Metal Z-clips are attached to the inside of the bar front panel.  Z-clips (model KMB-PC) available for purchase.

Slide panel into channel created by two pieces of wood.

END PANELS

9

INSTALLATION (CON’T)

Everything shown in brown is supplied by millworker.

Everything shown in brown is supplied by millworker.

Wood should be 3/4” thick to fit Z-clips

Model 

KMB-PC

 

Stainless Steel Z-CLIPS  

with 3/4” offset (24 PACK)

3/4”

1”

2-1/2”

Method A

Method B

Содержание Modular Bar Die

Страница 1: ...Krowne Metal Corporation 100 Haul Rd Wayne NJ 07470 Toll Free 800 631 0442 Fax 973 872 1129 sales krowne com krowne com Installation Manual Modular Bar Die...

Страница 2: ...se locations for hot cold water supply lines beverage line conduits and electrical conduit behind the underbar equipment this chase is accessible from the floor and runs the entire length of the bar F...

Страница 3: ...AL ICE BIN WITH BUILT IN COLD PLATE 24 26 22 5 17 41 30 9 10 Bar Sink Side View 24 26 17 5 12 41 30 9 10 4 5 30 41 10 R 68 R1 62 R2 5 R 68 5 5 6 3 Removable Panel Removable Panel 11 37 12 Flat Wall Si...

Страница 4: ...tions using the hex bolts and nuts supplied with equipment 7 16 ratchet and box wrench will be needed for this step Set units in place according to the CAD drawings provided with equipment in the box...

Страница 5: ...g equipment such as bottle coolers mug frosters back bar and glass washers can be placed into their designated sections according to the floor plan Bottle coolers and mug frosters should be installed...

Страница 6: ...ls and hidden screws meaning they make accessing the underside of the bar very easy and the screws cannot be seen by customers making it a much nicer finish Metal Z clips are attached to the inside of...

Страница 7: ...and 19 clear depth or service shall be available at accessible tables within the same area OPTIONS Confirm size with local codes 36 to 60 depending on local code requirements BUILT IN OUTLETS MYLAR T...