© Termo-tehnika, d.o.o.
17-16-27-3033-00
23
07/2016
IMPORTANT
In case the overheating is not successful in 12 hours, the function turns of
and continues with normal heating.
7. “Quick heating” of water
One-time quick heating of water is turned on by holding the
key for approx. 20 seconds
(the indicator on the key flashes). After reaching the desired water temperature the indicator
turns off. We can end the quick overheating early by pressing the
key again.
NOTE
During the operation of quick heating the HT indicator blinks.
IMPORTANT
In case the heating is not successful in 12 hours, the function turns of and
continues with normal heating.
7.7 Settings
1. Setting the water temperature:
pressing the key
or
for the first time displays the
currently set temperature, additionally pressing the key
or
(in the time frame of 8s)
triggers its modification. If we wait for 5s, the new setting will be stored after the blinking stops.
2. Switching between various operation programmes:
switching between various operation
programmes is performed by pressing the
key The chosen operating mode is indicated by
the illuminated indicator for operation and the reading when the
key is pressed for the first
time (see table above). Pressing the key
in the time frame of 8 seconds switches between
available operating programmes.
3. Display and settings of parameters
You can enter the menu displaying the parameters by shortly pressing keys
and
at the
same time, we can move between the displays themselves with the key
or
.
When the desired parameter has been chosen, we have to wait for 8s, then the value of the
chosen parameter is displayed for 8s. After 8s the display returns into its basic menu which
displays the current water temp. in the DHW.
4. Setting the temperature of the switch to the reserve heat source (only the automatic
programme P.4):
we enter the menu displaying the parameters by shortly pressing keys
and
at the same time, we switch between displays with the key
or
. (see chapter
for parameter display). Choose the parameter
L.1
, after a few seconds the set temperature
of the switch is displayed (factory set to +7°C). We can change the set temp. during its display
with keys
and
(from +5°C to +25°C).
After setting the desired value, wait for 8s; after the blinking stops, the setting is saved. The
safety time delay disables a restart of the compressor after the temperature drop under the
switching value (7°C) for 30 minutes.
5. Setting the time interval of automatic thermal disinfection:
you can enter the parameter
display menu by shortly pressing keys
and
at once; you can switch between displays
with the key
or
(see chapter for parameter display). Choose the parameter
L.2
, after a
couple of seconds the set interval of overheating is displayed (factory set to 14 days). During
the display of the set value no. of days, it can be modified with the key
or
(from 7 to