NOTE
Removing the coolant must be performed in accordance with directive ES
842/2006 and other national and local regulations.
5
Technical description
5.1 General
This device is a heat pump for heating DHW in residential or small business premises where
the daily use of hot water does not exceed 700 litres. When heating DHW, the heat pump also
cools the room where it is located. Thus the heat pump can be used for heating DHW as well
as for cooling rooms; here we must point out that the heat pump will cool the room only if there
is a need for heating DHW. If there is no need, the heat pump will not cool the room.
NOTE
For maximal efficiency and economical use, we advise to use air from rooms
where waste heat is generated (DHW rooms, laundries, kitchens, basements,
pantries ...) and that the air temperature is as high as possible.
Dimensions:
Picture 1: Heat pump dimensions
Mark
Dimension
B
480
H
780
T
290
T1
420
1
Compressor
9
Electrical boiler
2
Condenser
10
Mg. Anode
3
Dehydrator
11
Safety thermostat sensor
4
Expansion valve
12
High-pressure switch
5
Evaporator
13
DHW sensor
6
Fan
14
Solar heat exchanger
7
Magnet valve
15
DHW heat exchanger
8
Expansion valve sensor
16
Buffer tank for DHW