9.12.3
Menu 4-4 "Manual Actuator Test"
The actuator test is used to test the actuators installed on the machine. An actuator can only be
tested if power is flowing through it. In the manual actuator test the actuator must therefore be
controlled manually for a short time to be able to determine if there are any errors in the
actuator system.
Caution!
The PTO must not be turning during the actuator test.
The tractor hydraulics must be deactivated.
L400251
DL400270
Figure 90
Displaying the menu
Main menu 4 "Service" is called.
•
You can select menu 4-4
with the rotary potentiometer. The icon is shown in
reverse colours.
•
Press the rotary potentiometer.
The display shows menu 4-4 "Manual actuator test".
Selecting the actuator
•
Select the actuator with the rotary potentiometer.
The selected actuator is shown in reverse colours.