Commissioning
26
Pos : 15.14 /BA/Ers tinbetriebnahme/Eas yC ut/Anbau Weiste-Drei ec k @ 3\mod_1204640890345_78.doc @ 71160
5.4
Installation of Weiste triangle
AFL 245-0-007
1
Fig. 6:
Pos : 15.15 /BA/Sic herheit/Gefahrenhinweise/Mähwer ke/Warnung Anbau des Kuppeldr eiec ks ( Weis te Dreiec k) @ 3\mod_1204638378407_78.doc @ 71102
Warning
Installation of the triangle linkage (Weiste triangle)
Effect: Danger to life or serious injuries. Considerable damage to the machine
Observe manufacturer's operating instructions for the triangle linkage!
Pos : 15.16 /BA/Ers tinbetriebnahme/Eas yC ut/Anbau Weiste-Drei ec k Text @ 3\mod_1204638631735_78.doc @ 71179
For the installation of the front-mounted disc mower, a Weiste triangle (1) is attached to the front
hydraulics. Adjust the top suspension arm in such a way that the triangle is inclined slightly
forward.
Pos : 15.17 /BA/Ers tinbetriebnahme/Eas yC ut/Vor ber eitung am Fr ontsc hei benmäher EC 28/32 28P/32P 28M @ 10\mod_1221659810103_78.doc @ 136162
5.5
Preparation on the front-mounted disc mower
EC-1-005
Fig. 7:
•
Push the PTO shaft (3) with full protection (4) onto the PTO shaft end of the machine.
•
The safety mechanism must engage
•
Secure the PTO shaft guard (2) against turning with pipe clamp (2).
Pos : 15.18 /BA/-----Seitenumbruc h------ @ 0\mod_1196175311226_0.doc @ 4165