background image

DK

S

N

P

GR

 www.docuthek.com

D

GB

F

NL

I

E

TR

CZ

PL

RUS

H

© 2014 Elster GmbH · Edition 11.14

Safety

Please read and keep in a safe place

 Please read through these instructions 

carefully before installing or operating. Following the 
installation, pass the instructions on to the opera-
tor. This unit must be installed and commissioned 
in accordance with the regulations and standards 
in force. These  instructions can also be found at 
www.docuthek.com.

Explanation of symbols

 • 

,   ,   ,   

... = Action

 

= Instruction

Liability

We will not be held liable for damage resulting from 
non-observance of the instructions and non-com-
pliant use.

Safety instructions

Information that is relevant for safety is indicated in 
the instructions as follows:

 DANGER

Indicates potentially fatal situations.

 WARNING

Indicates possible danger to life and limb.

 CAUTION

Indicates possible material damage.

All interventions may only be carried out by qualified 
gas technicians. Electrical interventions may only be 
carried out by qualified electricians.

Conversion, spare parts

All technical changes are prohibited. Only use OEM 
spare parts.

Changes to edition 09.

The following chapters have been changed:
–   Separate operating instructions for VG 6 – 15/10, 

see www.docuthek.com 

 Kromschröder 

 

Products 

 03 Valves and butterfly valves 

 

Solenoid valves for gas VG 

 VG 6 – VG 15/10

Contents

Operating instructions

D

GB

F

NL

I

E

GB-1

4440

Translation from the German

Solenoid valve for gas 

VG 0/5 – VG 65

Solenoid valve for gas VG 0/5 – VG 65. . . . 
Contents  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Checking the usage . . . . . . . . . . . . . . . . . . . . . 

Intended use  . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Type code  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Part designations . . . . . . . . . . . . . . . . . . . . . . . . 2

Type label. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Installation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Wiring  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Tightness test . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Commissioning. . . . . . . . . . . . . . . . . . . . . . . . . 4

Setting the flow rate . . . . . . . . . . . . . . . . . . . . . . 4
Setting the start gas rate  . . . . . . . . . . . . . . . . . . 4

Replacing the solenoid actuator  . . . . . . . . . . 5
Replacing a defective damping unit. . . . . . . . 5
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Assistance in the event of malfunction  . . . . . 6

Technical data  . . . . . . . . . . . . . . . . . . . . . . . . . 7

Designed lifetime  . . . . . . . . . . . . . . . . . . . . . . . . 7

Logistics  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Certification  . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Declaration of conformity . . . . . . . . . . . . . . . . . . 8

Approval for Australia . . . . . . . . . . . . . . . . . . . . . 8

Eurasian Customs Union  . . . . . . . . . . . . . . . . . . 8

Contact  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Safety

Contents

Содержание VG 10/15

Страница 1: ...ed out by qualified gas technicians Electrical interventions may only be carried out by qualified electricians Conversion spare parts All technical changes are prohibited Only use OEM spare parts Changes to edition 09 12 The following chapters have been changed Separate operating instructions for VG 6 15 10 see www docuthek com Kromschröder Products 03 Valves and butterfly valves Solenoid valves f...

Страница 2: ...on box 4 Damping unit 5 Screw plug for inlet pressure pu 6 Screw plug for outlet pressure pd 7 VG 10 15 40 32 hexagonal nut actuator VG 40 65 cap Type label Rated voltage electrical power consumption instal lation position max inlet pressure pu max ambient temperature enclosure and medium see type label www kromschroeder com Osnabrück Germany VG CE 0063CM1188 Installation CAUTION Please observe th...

Страница 3: ... occurs Electric shocks can be fatal Before working on possible live components ensure the unit is disconnected from the power supply The solenoid actuator heats up during opera tion Surface temperature approx 85 C approx 185 F pursuant to EN 60730 1 Use temperature resistant cable 80 C 176 F Wiring to EN 60204 1 1 Disconnect the system from the electrical power supply 2 Shut off the gas supply Th...

Страница 4: ... Checking for external tightness 0 N2 1 5 x pu max 0 0 N2 1 5 x pu max 4 6 5 Open the solenoid valve 0 N2 1 5 x pu max 0 0 N2 1 5 x pu max 4 6 Pipeline leaking check the seal Checking for internal tightness 7 Close the solenoid valve N2 ca 6 mbar 0 0 8 9 After 60 seconds increase the text pressure to 1 5 x pu max N2 1 5 x pu max 0 0 10 Tightness OK open the pipeline Unit leaking remove the VG and ...

Страница 5: ...10 mm up 1 N bue 2 LV1 black 11 Screw the solenoid actuator into place 12 Release the gas supply VG L N LV1 4 3 6 5 7 8 9 10 11 12 13 Slide the O ring approx 10 mm up 1 N blue 2 LV1 black V N2 1 5 x pu max 15 17 14 19 18 20 16 13 Can be rotated max 3 x 360 Ad just the start gas rate 21 Tightness OK release the gas supply Replacing a defective damping unit 1 Disconnect the system from the electrica...

Страница 6: ...uator has been reinstalled N2 1 5 x pu max 14 In order to determine whether the VG is tight and closes securely check the internal and external tightness see page 4 Tightness test Check electrical installations in line with local reg ulations pay particular attention to the PE wire Assistance in the event of malfunction WARNING Electric shocks can be fatal Before working on possible live component...

Страница 7: ...0 60 Hz 120 V AC 10 15 50 60 Hz 24 V DC 10 15 Electrical connection of VG 10 15 40 32 plug with socket to EN 175301 803 cable gland PG 11 connection terminal 2 5 mm2 Electrical connection of VG 40 65 plug with socket to EN 175301 803 cable gland PG 13 5 connection terminal 2 5 mm2 Enclosure IP 54 Duty cycle 100 Power factor of the solenoid coil cos φ 1 Power consumption Voltage Type 24 V DC 120 V ...

Страница 8: ...ng before using for the first time If stored for longer than this the overall service life will be reduced by the corresponding amount of extra storage time Packaging The packaging material is to be disposed of in ac cordance with local regulations Disposal Components are to be disposed Certification Declaration of conformity We the manufacturer hereby declare that the prod uct VG marked with prod...