EN
page 38
5. MAINTENANCE
5.1
Routine maintenance
WARNING: The machine is not protected against pressurized water jets. Do not use
pressure cleaning system against the machine.
It is recommended to contact the seller of chemicals for proper cleaning instructions,
in order to have detailed indications on methods and products for the correct perio-
dical machine sanitation.
Do not use bleach or chlorine based detergents.
Daily cleaning is needed to ensure that the machine runs perfectly. The following shall be
carried out:
• Turn the machine in
"STAND-BY"
mode, by pressing the push-button
"C"
of the control
panel (see chap. 2).
• Remove the surface fi lters and clean them under running water. Drain the sump water
(see chap. 2.2.3).
• Remove the pump fi lter and clean with a brush and a water shower.
• Remove the arms by loosening the fi xing screws, and thoroughly clean them, and the
nozzles under running water.
• Reassemble the parts and reposition the wash pipes fi rmly in place.
• Clean the tank very carefully, using a water shower.
• It is recommended to leave the machine door open at the end of the day.
• Automatic cycle of machine self-cleaning/rinsing: recommended at each day end.
The machine should be in
"STAND-BY"
mode.
Push START button
"A"
; an automatic
cycle of 60 seconds will start, after this the machine will be in
"STAND-BY"
mode.
STAND-BY