EN
page 29
INSTALLER SECTION
1.5 Detergent dispenser installation
Electrical connection:
Consult the electric diagram enclosed with the dishwasher.
Water connection:
a) Properly assemble the injector (C), using the appropriate washers.
b) Connect the suction straw to the dispenser suction attachment (see fig 5 point A).
c) Connect the flow straw to the other dispenser attachment and the flow connector (see
fig. 5 point B).
d) insert the straw with filter into the detergent canister.
e) Prime the detergent and proceed with the dosage phase
Dosage:
The detergent dosage flow can be regulated with a screwdriver as indicated in fig. 6. Every
2 cm of product sucked into the tube corresponds to 0,25 cm3 equal to 0,3 g (with 1,2 g/
cm3 density). See also par. 7.3.
N.B.: A dispenser with a conductivity probe in the tank is recommended
.
pict. 5
GERMAC
15185
Ø 8
SEKO
15108/E
Ø 10
pict. 6
A
B
C
A
B
C
PROBLEM
CAUSES AND REMEDY
Water leaks from rins aid suction tube
The suction valves 10705/D and flow do not seal due to foreign bodies is
the clamping seats. Clean valves 10705/D, check if the rinse aid suction
filter is present. Make sure there are no crystals or solid pieces inside the
canister which could be due to old, dried-out product.
The dispenser does not suck up rinse aid
a) The flow valve 10705/D does not seal due to foreign bodies in the
clamping seats. Clean the valve 10705/D, check if the rinse aid suction
filter is in place.
b) The piston washer does not seal because it is ruined. Replace the
washer with an original.
c) Check that membrane 10705/O is intact.
Содержание gr300