KROMA
TELECOM
PROFESSIONAL
MONITORS BM5414/20
BM5414/20
15
6.3.1. OPTION: AUTO SET UP
It can be carried out, by means of the set Generator/ Analizer KROMA DG5400
and probe AK4400X50 especially designed for this use.
When CAL key is pressed, will appear a flashing message in the lower line,
requesting the technical password. If the password is correct, the system will
permit pass to one of the auxiliary inputs, (AUX RGB or AUX CCVS). In the same
menu, will appear the message "SELECT INPUT: AUX CCVS however; you
could select any of the available inputs by pressing the keys associated to the
inputs (AUX, CCVS, CDV).
SET UP MENU
AUTO SET UP
CRT/REF :
MANUAL SET UP LEARN PROBE
SELECT INPUT: AUX CCVS
Figure 5
In order to obtain an accurate adjustment, the monitor carries out a different
adjustment for the digital inputs. For this purpose select one of the digital inputs
(S1 or S2) and the system will carry out an independent adjustment of any
another input. In this mode, when you change a digital input, the system will
program the values of HLs and the LLs, corresponding to the digital adjustment.
Consequently, will note a better response of the monitor.
Independently of the type of input selected, this should coincide with the DG54xx.
Once selected the inputs signal and the phosphor reference, press the key CAL
in order to start the adjustment. If during any step you doubt of any parameter,
you could stop the process by pressing ESC.
Next appears the message: "PUT PROBE & PRESS CAL", put on the
optical probe on the center of the screen and fix it to the center of the window
that it will appear after a short time. Starting from this moment and during the
adjustment time, don´t move the probe and not disconnect the A.S.U connector.
because it will block the system owing initiate again the monitor. However, their
parameters won't be affected.
The adjustment is finished when appears the message: "Ok AUTO SET UP
SUCCESSFULLY."