background image

© 2012 Elster GmbH

Safety

Translation from the German

Operating and installation instructions

10.2.1.4 Edition 01.12 GB

Liability

We will not be held liable for damages resulting from non-observance 
of the instructions and non-compliant use.

Safety instructions

Information that is relevant for safety is indicated in the instructions 
as follows:

 DANGER

Indicates potentially fatal situations.

 WARNING

Indicates possible danger to life and limb.

 CAUTION

Indicates possible material damage.

All work and settings in the “Expert” chapters may only be carried 
out by a qualified technician. Electrical interventions may only be 
carried out by a qualified electrician. The heating system must be 
disconnected from the power supply before any electrical work is 
carried out on the unit.

Conversion

All technical changes are prohibited. 

Transport

On receipt of the product, check that the delivery is complete. Report 
any transport damage immediately. 

Storage

Store the product in a dry place. Ambient temperature: see Techni-
cal data.

Please read and keep in a safe place

 Please read through these instructions carefully before 

installing or operating. Following the installation, pass the instruc-
tions on to the operator. 
These instructions can also be found at www.docuthek.com.

Explanation of symbols

 • 

,  1 ,  2 ,   

...  = Action

 

= Instruction

Safety

Lago FB OT digital remote control

Содержание Lago FB OT

Страница 1: ...echnician Electrical interventions may only be carried out by a qualified electrician The heating system must be disconnected from the power supply before any electrical work is carried out on the uni...

Страница 2: ...om sensor correction 15 P04 Hot water according to program 15 User Questions 15 How do I switch to summer winter time 15 How do I set the heating controller so that it gets warm sooner in the morning...

Страница 3: ...62 00 20 Expert Checklist for commissioning 20 Accessories 21 Outside sensor AF 21 Sensor values 21 Troubleshooting 21 Technical data 22 Glossary 23 Flow temperature 23 Desired and actual temperature...

Страница 4: ...he Open Therm Smart Power function the display of the Lago FB OT remote control is illuminated during operation The function is only guaranteed within the specified limits see page 22 Technical data A...

Страница 5: ...diness OFF Heating and hot water preparation OFF frost protection operation only 1 Automatic mode 1 Heating according to heating program 1 hot water according to parameter 04 2 Automatic mode 2 Heatin...

Страница 6: ...hase desired night time temperature The desired temperature for the hot water can be adjusted The desired hot water temperature can only be set if the system has a storage tank Factory setting Desired...

Страница 7: ...tion after a few seconds without action Set operating mode The operating mode determines how the heating controller works Whether the heating system is to be controlled automatically or man ually duri...

Страница 8: ...Set heating program 1 Heating program 1 is assigned to automatic mode 1 It is used to define the heating times for the working week Mon Fri and the weekend Sat Sun You can set three heating times per...

Страница 9: ...order to apply it set the operating mode to 1 Automatic mode 1 see page 7 Set operating mode Example Display of the heating times for heating program 1 Heating takes place from Monday to Friday betwe...

Страница 10: ...rn the selector switch back to The heating program 2 has been set In order to apply it set the operating mode to 2 Automatic mode 2 see page 7 Set operating mode Holiday setting holiday duration In ho...

Страница 11: ...layed and flashes 3 Use the rotary knob to set number of days holiday to 0 4 Press the OK button to confirm 5 Finally turn the selector switch back to The last operating mode selected is displayed Hea...

Страница 12: ...Press the OK button to confirm Reduction starts straight away 5 Finally turn the selector switch back to Early ending of heating time 1 Turn selector switch to Eco 2 Press the OK button The run time r...

Страница 13: ...Press the OK button to confirm 6 After you have made the setting continue with step 2 if you want to change further parameters or turn the selector switch back to The table List of parameters P01 to...

Страница 14: ...d Increase the heat slope if the desired room temperature is not reached in combination with low outside temperatures If the desired room temperature is not reached in combination with high outside te...

Страница 15: ...on is not switched on In Summer mode parameter 04 must be set to 1 2 or 4 P04 4 24 hours hot water Example P04 3 If Automatic mode 1 was selected as the operating mode the heating controller will alwa...

Страница 16: ...em off during the summer In summer you should set the heating controller to the operating mode Summer mode This mode deactivates heating and the system is only used for hot water see page 7 Set operat...

Страница 17: ...ce or main living space of the heatcircuit on an internal wall in the living room Not in the vicinity of radiators or other devices that give off heat Anywhere if room sensor influence is switched off...

Страница 18: ...r users see page 13 User Set parameters WARNING Incorrect settings can cause malfunctions and damage the heating installation Only a qualified technician may change the parameters from no 06 A CODE NO...

Страница 19: ...ntered for adjustment of the Expert parameters The default setting for the heating controller is 0000 P06 Code no change Here you can specify your own code no Remember this code well The parameters 06...

Страница 20: ...The values are only accepted by the heat source if they are within this range P12 Transparent Slave Parameter 02 Setting for internal parameter 02 for heat source P12 255 255 The values are only accep...

Страница 21: ...s indicated in the display Example E 81 You can find the error numbers in the heat source instructions The display shows an error no between E001 and E255 Boiler error If there is an arrow in the disp...

Страница 22: ...P04 01 or 02 Should the actions described above fail to help please contact your heating engineer Please have ready the software version parameter P13 Technical data Voltage supply via BUS 15 18 V DC...

Страница 23: ...own too much while saving energy Heat source Heat source is generally the designation for the heating boiler It may also be a buffer storage tank however Heating time In the heating programs you can d...

Страница 24: ...ur local branch office agent The addresses are available on the Internet or from El ster GmbH We reserve the right to make technical modifications in the interests of progress Contact Contact Heating...

Отзывы: