9 Supplement
OPTISWITCH 3200 C • NAMUR
31357-EN-210702
Adjustment elements
Mode switch
Ʋ Min.
rising characteristic curve (High current when immersed)
Ʋ Max.
falling characteristics (Low current when immersed)
Potentiometer for switching point adapta-
tion
0.02 … 0.1 g/cm³ (0.0007 … 0.0036 lbs/in³)
Simulation key
simulation of a line break between sensor and process-
ing unit
Voltage supply
Operating voltage (characteristics ac-
cording to standard)
for connection to an amplifier according to NAMUR
IEC 60947-5-6, approx. 8.2 V
Off-load voltage
U
0
approx. 8.2 V
Short-circuit current
I
U
approx. 8.2 mA
Electrical protective measures
Protection rating
A suitable cable is required for maintaining the protec-
tion rating.
Housing material
Protection acc. to IEC 60529
Protection acc. to NEMA
Plastic
IP 66/IP 67
Type 4X
Aluminium
IP 66/IP 68 (0.2 bar)
IP 68 (1 bar)
Type 6P
Type 6P
Stainless steel (electro-polished)
IP 66/IP 68 (0.2 bar)
IP 68 (1 bar)
Type 6P
Type 6P
Stainless steel (precision casting)
IP 66/IP 68 (0.2 bar)
IP 68 (1 bar)
Type 6P
Type 6P
Altitude above sea level
up to 5000 m (16404 ft)
Protection class
II
Approvals
Depending on the version, instruments with approvals can have different technical data. For these
instruments, please note the corresponding approval documents. They are included in the scope of
delivery.