13
4 Mounting
OPTISWITCH 3200 C • NAMUR
31357-EN-210702
d
d 6
1
2
3
Fig. 4: Filling in the centre, emptying laterally
1 OPTISWITCH 3200 C
2 Discharge opening
3 Filling opening
The vibrating element should protrude into the vessel to avoid
buildup. For that reason, avoid using mounting bosses for flanges
and screwed fittings. This applies particularly to use with adhesive
products.
If OPTISWITCH 3200 C is mounted in the filling stream, unwanted
false measurement signals can be generated. For this reason, mount
OPTISWITCH 3200 C at a position in the vessel where no disturbanc-
es, e.g. from filling openings, agitators, etc., can occur.
Mounting socket
Inflowing medium