2.8 General requirements sensor
To secure the optimum functioning of the flowmeter, please note the following observations.
á
Install the flow sensor in a horizontal position in a slightly descending line.
á
Do not install the flow sensor in a lowered pipe section to avoid that water can collect in the
measuring tube.
á
Orientate the flow sensor such that the path of the acoustic signal is in the horizontal plane.
For exchanging the transducers, please keep a free space of 0.3 m / 11.81" around the
transducer.
2.9 Installation conditions
2.9.1 Inlet and outlet
Figure 2-8: Recommended inlet and outlet
1
≥
20 DN
2
≥
3 DN
INFORMATION!
Shorter inlet conditions (< 20 DN) are depending on the upstream pipe configuration.