6.4 Guidelines for maximum operating pressure
Notes
•
Ensure that the meter is used within its operating limits
•
All hygienic process connections have a maximum operating rating of 10 barg at 150
°
C /
145 psig at 302
°
F
Pressure / temperature de-rating for Titanium Gr 9 meters
Pressure / temperature de-rating for Titanium Gr 9 meters
Pressure / temperature de-rating for Titanium Gr 9 meters
Pressure / temperature de-rating for Titanium Gr 9 meters
(all meter sizes, with flanged connections as per EN 1092-1 and JIS B 2220)
(all meter sizes, with flanged connections as per EN 1092-1 and JIS B 2220)
(all meter sizes, with flanged connections as per EN 1092-1 and JIS B 2220)
(all meter sizes, with flanged connections as per EN 1092-1 and JIS B 2220)
X temperature [
°
C]
Y pressure [barg]
1
Standard tube and outer cylinder 316L (100 barg PED option) with PN100 flanges (sizes DN06...25)
2
Standard tube and outer cylinder 316L (100 barg PED option) with PN100 flanges (sizes DN40...80)
3
DIN 2637 PN63 flanges
4
Outer cylinder (63 barg PED / CRN option)
5
JIS 20K flanges
6
DIN 2635 PN40 flanges
7
JIS 10K flanges
8
Hygienic connections
MA_OPTIMASS_7000_en_151026_4001016303_R03.book Page 39 Monday, October 26, 2015 4:44 PM