2.1  Precautions

2.1.1  General notes

2.1.2  Electrostatic discharge

WARNING!

When you install the device, obey the conditions in the certificate of conformity.
You can download the certificate from our internet site.

DANGER!

This installation must agree with Chinese Law and NEPSI regulations. For more data, refer to 
the related NEPSI explosion protection certificates of conformity and these Chinese National 
Standards:

GB 505257

GB 505257

GB 505257

GB 505257: Code for construction and acceptance of electric device for explosion 
atmospheres and fire hazard electrical equipment installation engineering,

GB 3836.13

GB 3836.13

GB 3836.13

GB 3836.13: Electrical apparatus for explosive gas atmospheres 

 Part 13: Repair and 

overhaul for apparatus used in explosive gas atmospheres, 

GB 3836.15

GB 3836.15

GB 3836.15

GB 3836.15: Electrical apparatus for explosive gas atmospheres 

 Part 15: Electrical 

installation in hazardous area (other than mines), and

GB 3836.16

GB 3836.16

GB 3836.16

GB 3836.16: Electrical apparatus for explosive gas atmospheres 

 Part 16: Inspection and 

maintenance of electrical installation (other than mines)

DANGER!

The device contains a PTFE boundary wall between the process and the signal converter. Do not 
use the device in the process if the PTFE part is not resistant to corrosion by the tank product.

DANGER!

Risk of electrostatic discharge from:

the painted surfaces of the aluminium housing

the plastic protective sheathes (PVC, PVDF or PP) on single rod probes, and

the coated single cable probes (PFA, PP, PTFE, FEP)

DANGER!

Take the necessary antistatic precautions if:

you handle the device in potentially explosive atmospheres,

you install the device in potentially explosive atmospheres or

you use the device in potentially explosive atmospheres.

Install the device correctly to prevent electrostatic discharge. Make sure that all equipment is 
correctly grounded.

Make sure that the housing and adjacent objects do not rub together.

If dirt collects on the device, clean it with a damp cloth.

Содержание OPTIFLEX 2200 C

Страница 1: ...NEPSI applications Supplementary Instructions for NEPSI applications Supplementary Instructions for NEPSI applications OPTIFLEX 2200 C F OPTIFLEX 2200 C F OPTIFLEX 2200 C F OPTIFLEX 2200 C F Supplemen...

Страница 2: ...ousing for dust applications 16 2 2 3 Process pressure 16 3 Electrical connections 17 3 1 General notes 17 3 2 Terminal compartment 17 3 2 1 How to open the terminal compartment 17 3 2 2 How to close...

Страница 3: ...hne com 03 2019 4005066003 AD NEPSI OPTIFLEX2200 R03 en OPTIFLEX 2200 C F 5 4 Returning the device to the manufacturer 28 5 4 1 General information 28 5 4 2 Form for copying to accompany a returned de...

Страница 4: ...ata for the non Ex version in the Handbook shall be valid in its current version provided that it is not rendered invalid or replaced by these supplementary instructions WARNING Installation commissio...

Страница 5: ...ary The Ex iaD approved device is suitable for use in potentially explosive atmospheres of all flammable substances in Dust Zones 20 21 when fitted with appropriate options 1 4 2 Ex d ia and Ex iaD tD...

Страница 6: ...assive 4 20 mA passive HART output option Ex ia approvals HART output option Ex ia approvals HART output option Ex ia approvals HART output option Ex ia approvals Intrinsically safe circuit data 4 20...

Страница 7: ...ices made outside of China 1 Approval logo 2 NEPSI certification agency code 3 Types of device protection including approved Gas Groups and temperature classes T6 T3 or T2 depends on the probe type eq...

Страница 8: ...ve gas atmospheres Part 15 Electrical installation in hazardous area other than mines and GB 3836 16 GB 3836 16 GB 3836 16 GB 3836 16 Electrical apparatus for explosive gas atmospheres Part 16 Inspect...

Страница 9: ...risk of an increase in electrostatic charge caused by compressed air and dust locations near machines that use friction locations near systems that apply electrons as a spray e g near electrostatic p...

Страница 10: ...ure must be in the approved limits For more data refer to Pressure and temperature ranges in the Installation chapter of the handbook Definitions Figure 2 2 Definitions 1 Compact version Signal conver...

Страница 11: ...08 single cable probe HT version 2 mm 0 08 single cable probe other versions All other probe types C F C F C F C F T6 54 129 52 125 53 127 60 140 T5 70 158 70 158 70 158 60 140 T4 80 176 80 176 80 176...

Страница 12: ...212 T4 79 174 77 170 78 176 85 185 76 169 67 152 70 158 110 230 73 163 57 134 62 143 135 275 T3 71 160 51 124 57 134 150 302 68 154 180 1 356 1 65 149 200 1 392 1 T2 60 140 250 1 482 1 54 129 300 1 57...

Страница 13: ...C F C F C F C F T6 51 123 49 120 49 120 60 140 T5 70 158 70 158 70 158 60 140 T4 80 176 80 176 80 176 60 140 Temperature class Minimum ambient temperature Min flange temperature 2 mm 0 08 single cabl...

Страница 14: ...156 43 109 54 129 150 302 65 149 180 1 356 1 62 143 200 1 392 1 T2 54 129 250 1 482 1 47 116 300 1 572 1 1 Make sure that gasket temperature is in the specified limits For more data refer to the handb...

Страница 15: ...176 80 176 80 176 80 176 90 194 79 174 79 174 76 169 75 167 77 170 76 169 100 212 78 172 77 170 72 161 70 158 74 165 73 163 110 230 76 169 76 169 68 154 64 147 70 158 69 156 120 248 75 167 74 165 64 1...

Страница 16: ...devices Ex iaD and Ex iaD tD devices If the ambient and flange temperatures of the device are not more than values given in the table for devices that operate in Dust Zones the surface temperature of...

Страница 17: ...refer to the device nameplate If ambient temperature 65 C 149 F use heat resistant cables cable glands and cable entry plugs certified for continuous operation above 80 C 176 F WARNING If dirt collect...

Страница 18: ...es Ex d Ex t approved devices Ex d Ex t approved devices After the time given in the table that follows remove the cover stop 1 i Use a 2 5 mm Allen wrench Remove the terminal compartment cover 2 INFO...

Страница 19: ...to prevent damage to the thread and the gasket Make sure that the terminal compartment cover is tight Use a 2 5 mm Allen wrench to attach the cover stop 1 Make sure that the cover stop 1 screw is tig...

Страница 20: ...e device to the equipotential bonding system for the hazardous location Remote Field version There is a terminal on the wall support and a terminal at the bottom of the probe housing that can be used...

Страница 21: ...rical wires are safely isolated other electrical wires ground etc and rated for a test voltage 500 VRMS If it is necessary make sure the electrical wire insulation gives good protection from corrosion...

Страница 22: ...the 4 20 mA passive HART output option Figure 3 5 Electrical schematic for Ex ia and Ex iaD approved equipment with the 4 20 mA passive HART output option Level transmitter with the FOUNDATION fieldbu...

Страница 23: ...two separate compartments The electronics in the electronics block compartment are Ex ia approved and the terminals compartment is Ex d Ex t approved Figure 3 7 Figure 3 8 Remote Field version Compar...

Страница 24: ...er to Maximum intrinsically safe values for the electrical circuit on page 21 3 6 4 Electrical schematic WARNING Use only Ex d approved cable glands and plugs for Ex d applications Use only Ex t appro...

Страница 25: ...ure 3 10 Electrical schematic for Ex d ia and Ex iaD tD approved equipment without galvanic isolation 1 Galvanically isolated power supply 2 Power supply 3 Resistor for HART communication 4 Non Ex zon...

Страница 26: ...aptors Ex d approved Ex t applications Ex t applications Ex t applications Ex t applications Are the cable glands plugs and adaptors Ex t approved Ex ia applications Ex ia applications Ex ia applicati...

Страница 27: ...d to return your device for inspection or repair make sure that you send it to the correct manufacturer and obey the instructions that follow INFORMATION For more data about regular inspections and ma...

Страница 28: ...uarding the health and safety of the personnel the manufacturer may only handle test and repair returned devices that have been in contact with products without risk to personnel and environment This...

Страница 29: ...artment Name Tel no Fax no and or Email address Manufacturer s order no or serial no The device has been operated with the following medium This medium is radioactive water hazardous toxic caustic fla...

Страница 30: ...6 NOTES 30 OPTIFLEX 2200 C F www krohne com 03 2019 4005066003 AD NEPSI OPTIFLEX2200 R03 en...

Страница 31: ...NOTES 6 31 OPTIFLEX 2200 C F www krohne com 03 2019 4005066003 AD NEPSI OPTIFLEX2200 R03 en...

Страница 32: ...ices Head Office KROHNE Messtechnik GmbH Ludwig Krohne Str 5 47058 Duisburg Germany Tel 49 203 301 0 Fax 49 203 301 10389 info krohne com KROHNE 03 2019 4005066003 AD NEPSI OPTIFLEX2200 R03 en Subject...

Отзывы: