INSTALLATION
2
11
OPTIFLEX 2200 C/F
www.krohne.com
03/2019 - 4005066003 - AD NEPSI OPTIFLEX2200 R03 en
Compact versions
EPL Ga/Gb: Ex ia and Ex d ia devices
Temperature
class
Maximum ambient temperature
Max. flange
temperature
Ø2 mm / Ø0.08
¨
single cable probe
(HT version)
Ø2 mm / Ø0.08
¨
single cable probe
(other versions)
All other probe types
[
°
C]
[
°
F]
[
°
C]
[
°
F]
[
°
C]
[
°
F]
[
°
C]
[
°
F]
T6
+54
+129
+52
+125
+53
+127
+60
+140
T5
+70
+158
+70
+158
+70
+158
+60
+140
T4
+80
+176
+80
+176
+80
+176
+60
+140
Temperature
class
Minimum ambient temperature
Min. flange
temperature
Ø2 mm / Ø0.08
¨
single cable probe
(HT version)
Ø2 mm / Ø0.08
¨
single cable probe
(other versions)
All other probe types
[
°
C]
[
°
F]
[
°
C]
[
°
F]
[
°
C]
[
°
F]
[
°
C]
[
°
F]
T6...T2
-40
-40
-40
-40
-40
-40
-20
-4