Specifications 

 

THE V6 POWERED STUDIO MONITOR 

Frequency Response 

 

58Hz -22kHz 

±

2dB  

High Frequency Driver 

 

Shielded 1” (25mm) Silk Soft Dome 

Low Frequency Driver 

 

Shielded 6” (203.2mm) Polyvinyl   

Cabinet   

 

 

13.4 liter bass reflex and ¾” MDF construction, 

Neutral Gray Zolatone® Finish 

Dimensions 

 

 

9” W x 13-1/16” H x 12” D (279mm W x 406mm H x 304.8mm D) 

Net Weight 

 

 

38 lbs. ea.  (17.27 kg) 

 

THE V6 AMPLIFIER 

Power Rating 

 

 

30 Watt HF Amplifier   60 Watt LF Amplifier   

Signal to Noise   

 

>90dB 

T.H.D    

 

 

<.07% at full output 1khz 

Input Impedance  

 

10k Ohms Balanced Input 

Gain 

 

 

 

26dB 

Power Consumption 

 

100 VA 

 

THE V6 CROSSOVER 

Crossover Frequency 

 

1.96kHz 

Crossover Slope   

 

HF -12dB/Octave Butterworth, LF -18dB/Octave Butterworth 

Subsonic Filter   

 

12dB/Octave   -3dB @ 35Hz 

 

FEATURES 

Neutrik® Combo Connector accepts XLR and ¼” phone and TRS connectors 
IEC Mains Connector 
System Gain Control (controls input sensitivity) 
LED Power Indicator 
Power On/Off Muting and Delay 
 
 
 

 

 

 

 

 

Содержание V6

Страница 1: ...M O D E L V 6 VIDEO SHIELDED BI A M P L I F I E D S T U D I O M O N I T O R KRK SYSTEMS LLC 5452 BUSINESS DRIVE HUNTINGTON BEACH CA 92649 TEL 714 373 4600 FAX 714 373 0421 WEB SITE WWW KRKSYS COM EMAIL SALES KRKSYS COM ...

Страница 2: ...ds on music recording industry professionals have created the need for better monitor performance at more affordable prices The V Series class of Powered Studio Monitors was created to address these needs Please take a few moments to review the information in this guide FEATURES OVERVIEW 1 Neutrik Combo Connector accepts XLR phone and TRS connectors 2 System Gain Control adjusts overall gain of th...

Страница 3: ... front baffle when power is applied NOTE MAKE SURE THAT THE VOLTAGE INDICATOR FOUND IN THE MIDDLE PORTION OF THE IEC MAINS CONTROL IS SET TO THE CORRECT VOLTAGE SETTING FOR YOUR VOLTAGE CHANGING VOLTAGE To change the voltage remove the power cord pry off the fuse block with a small flathead screwdriver look for indent on the left inside of the power cord insert Slide the circuit board out of the f...

Страница 4: ...ss low frequency interaction excluding any interaction with the mixing console Positioning Your Monitors Positioning your monitors correctly in the studio is critical to their performance Typically they should be placed so that that the listening position is fully covered with all monitors resting on the same horizontal plane A great way to test a monitor for its imaging capability is to play back...

Страница 5: ...t up would look like the set up in Figure 3 This set up may not be practical or possible in your room Once you have set up your monitors Listen to some program material that you know has low frequency information recorded on it Different locations may create a phase misalignment Most Subwoofers have a phase switch on them Flip the phase switch The bass response volume will either increase or decre...

Страница 6: ...5 Figure 3 ...

Страница 7: ...you need to adjust the input sensitivity by the SYSTEM GAIN pots see page 2 for each monitor so that all channels have exactly the same SPL output at the listening position Although this can be done simply by listening to each channel one at a time and adjusting for relative levels we recommend using an SPL meter and filtered noise pink noise to test each channel independently Simply take a readin...

Страница 8: ...7 when transporting or shipping your V6 ...

Страница 9: ...ate less heat resulting in no signal drift or component variations to provide a more stable image Balanced Power KRK s amplifier construction is proven durable and straightforward Output wattage is balanced to optimize LF and HF driver performance Your V6 monitor uses a toroidal power transformer for the lowest possible hum and minimum noise artifacts No Compression Your V6 contains no signal comp...

Страница 10: ... working Exchange the audio input cable from the non working monitor to the working unit This will determine whether it s really the monitor a faulty cable or some other glitch in the audio chain If the monitor is still not responding it should be returned to the dealer where you purchased it or to KRK for servicing Problem If the monitor suddenly stops working Turn the monitor send down or off Re...

Страница 11: ... the System section on page 4 of this manual to ensure that the AC mains is matched to the operating voltage requirements All audio equipment should use the same ground point Check all other devices using the same AC output in the building like dimmers neon signs TV screens and computer monitors These devices should not be using the same circuit For updated Troubleshooting information please visit...

Страница 12: ...11 ...

Страница 13: ...a 17 27 kg THE V6 AMPLIFIER Power Rating 30 Watt HF Amplifier 60 Watt LF Amplifier Signal to Noise 90dB T H D 07 at full output 1khz Input Impedance 10k Ohms Balanced Input Gain 26dB Power Consumption 100 VA THE V6 CROSSOVER Crossover Frequency 1 96kHz Crossover Slope HF 12dB Octave Butterworth LF 18dB Octave Butterworth Subsonic Filter 12dB Octave 3dB 35Hz FEATURES Neutrik Combo Connector accepts...

Страница 14: ...13 KRKandV6areregisteredtrademarksofKRKSystems Inc ...

Страница 15: ...nstructions The Safety instructions should be kept for future reference WARNING Power Sources This equipment should be operated only from power source indicated on the product This equipment is intended to be used with a main power system with a grounded neutral conductor The third grounding pin is a safety feature do not attempt to bypass or disable Servicing Refer all Servicing to qualified pers...

Страница 16: ...sk of electric shock to humans The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the product CAUTION To reduce the risk of electric shock do not remove the cover No user serviceable parts inside Refer servicing to qualified service person WARNING To prevent ...

Страница 17: ...ualifié Attention Lire les instructions Prendre connaissance de toutes les consignes de sècurité et d exploitation avant d utiliser le matériel Avertissement Alimentations Ne faire fonctionner ce matériel qu avec la source d alimentation indiquée sur I appareil Ce matériel doit être utilisé avec une alimentation principale comportant un fil de terre neutre Le troisième contact de mise à la terre c...

Страница 18: ...l intérieur d un triangle équilatéral est employé pour alerter les utilisateurs de la présence d instuctions importantes pour le fonctionnement et l entretien service dans le livret d instructions accompagnant l appareil ATTENTION Pour eviter les risques de choc électrique ne pas enlever le courvercle Aucun entretien de piéces intérieures par l usager Confier l entretien au personnel qualifié AVIS...

Отзывы: