- 2 -
N° : 578.027.120-UK-1309
Start up procedure :
1 - Ground the pump.
2 - Unscrew the air regulators (B and D).
3 - Interconnect the equipment with the air pressure network (clean air - 6 bar / 87 PSI maxi). Install a
water drop, model 3/8 if necessary.
4 - Connect all the hoses (air hoses and material hose) as well as the spray gun.
5 - Immerse suction rod (F) and drain hose (G) into material container.
6 - Open drain valve (H).
7 - Open the motor - valve (E) air supply - (P
t
1 bar / 14.503 PSI).
8 - Gradually screw fluid regulator (D) so that the pump runs slowly.
9 - Check drain hose. When material flows out regularly, close drain valve (H).
10 - Point the spray gun, not supplied with air, towards the material container and press the trigger.
11 - Supply air pressure to the spray gun.
12 - Adjust fluid regulator (D) to get the appropriate material pressure and flow rate.
13 - Gradually open air regulator (B) to adjust spraying air to obtain the required spray pattern.
Â
If the pump is equipped
with an air regulator (K),
screw this one, then adjust
the fluid regulator (D).
Î
The pressure read at the
air motor regulator (K) must
exceed by 1.5 bar / 22 psi
(minimum) the fluid pressure
indicated by the fluid
regulator (D).