Possibilities for spray pattern adjustment
Fig. 5: Adjusting the spray pattern
The spray pattern can be influenced as follows:
n
Adjust atomisation air pressure via pressure reducer or air regulator (Fig. 5/2).
n
Adjust fluid pressure with supply by pumps or pressure container.
n
Adjust needle stroke with adjustment screw (Fig. 5/3).
n
Adjust width of the spray stream with jet regulator (Fig. 5/1).
n
Selection of the nozzle size.
4.4 Interrupting operation
1.
Terminate spraying process by releasing the draw-off lever.
2.
Interrupt the feed of spray fluid. For this, empty the fluid container, unscrew the suction con-
tainer or switch off the pump or pressure container.
3.
If necessary, clean the hand held spray gun (
Chapter 5.2.1 „Clean hand held spray
).
hand held spray gun HS-25
ENGLISH
HS-25, HS-25 HV1, HS-25 HV3
GB–11
Содержание HS 25 Series
Страница 28: ......