1.
Chapter 6.5 ‘Shutting down’ on page 24
).
2.
If necessary, secure pump or pressure container for the fluid against restart.
Fig. 8: Connect cleaning products
3.
Interrupt the external fluid supply.
4.
Connect a container with detergent to the fluid connection ( Fig. 8/1 or 2) or fill container
with detergent fluid.
5.
Switch on the compressed air supply.
6.
Where applicable, switch on pump or pressure container for spray fluid.
7.
Begin spraying process by pulling the pull lever ( Fig. 8/3).
8.
Spray until the cleaning product runs clear.
9.
End spraying process by releasing the pull lever ( Fig. 8/3).
10.
End the cleaning product supply.
11.
Blow out the cleaning product residue by briefly pulling the pull lever ( Fig. 8/3).
12.
Switch off the compressed air supply and secure it against restart.
13.
Clean the outside of the device with a cloth dipped in cleaning product.
Operating instructions
T-Dok-009-GB-Rev.3
[email protected], www.krautzberger.com
GB–28