APPLIANCE INSTALLATION (cont.)
Installation Clearance
Leveling
Ensure the floor where the unit is to be located is level or shim the unit to level it.
Stabilizing
All models are supplied with casters for your convenience. It is very important, however, that the cabinet be installed in a
stable condition with the front wheels locked while in use. Should it become necessary to lay the unit on its side or back for
any reason, allow at least 24 hours before start-up to allow compressor oil to flow back into place. Failure to meet this
requirement can cause compressor failure and unit damage, which would not be covered by your warranty.
NOTICE:
Unit repairs will not be subject to standard unit warranties if due to improper installation procedures.
Electrical Connection
Refer to the amperage data on the
Technical Information
table, the serial tag, your local code or the National Electrical Code to
be sure that unit is connected to the proper power source.
DANGER
The unit must be turned OFF and disconnected from the power source whenever
performing service, maintenance functions or cleaning the refrigerated area. Failure to
comply may result in Death or Severe Personnel Injury.
69K-768/ 69K-752
69K-767
2”
51mm
69K-767
58 in
1473 mm
Max Door Swing
Clearance
69K-768
53 in
1346 mm
Max Door Swing
Clearance
69K-752
59.5 in
1511 mm
Max Door Swing
Clearance