background image

KRATOS GAS FLOOR FRYERS 

  

OWNER’S MANUAL 

  Page 18 

Revision 07/29/2021 

202320237035085  Flue Top 

 

 

 

202320237044023  Flue Top 

 

 

 

202320237034030  Flue Top 

 

 

20137035013   

Flue Wrap 

 

 

20137058004   

Flue Warp 

 

 

 
 

  

 

 
 
 
 
 

 
 

No. 

Part # 

Description 

F3 

F4 

F5 

20137056003 

Door Assembly Complete 

 

 

20137058003 

Door Assembly Complete 

 

 

 

302190245 

Door Magnet 

302090001   

6” Adjustable Leg 

 

30302090082  Caster Kit, (2 Front Swivel w/Brake, 2 Rear Fixed) 

OPT 

OPT 

OPT 

302110471 

Fry Basket (13.25” L x 6.5” W x 6” D) 

 

 

302110484 

Fry 

Basket (17.5” L x 9.25” W x 6” D) 

 

 

 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 

Содержание 29Y-010

Страница 1: ...on service or maintenance can cause property damage injury or death Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment If installing...

Страница 2: ...information here Date of Purchase _________________________________ Dealer Purchase from _________________________________ Name of Installer ________________________Phone Number ______________________...

Страница 3: ...tood even though not dangerous FIRE HAZARD FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Keep area around appliances...

Страница 4: ...ull service solution RETAIN THIS MANUAL FOR FUTURE REFERENCE MODELS This manual is for Kratos Gas Floor Model Fryers with 35 40 pound 29Y 010 50 55 pound 29Y 011 and 70 100 pound 29Y 012 capacities Th...

Страница 5: ...d 12 W C for propane The fryer comes with NPT male connector on a pipe allowing you to connect with either a or NPT female connector Model Gas Type Manifold Pressure Number of heat tubes BTU Rate per...

Страница 6: ...ust then be signed by the carrier representative Driver If the bill is not signed the carrier may refuse the claim The carrier can supply the necessary forms A request for inspection must be made to t...

Страница 7: ...ion Improper leveling may void warranty When this appliance is installed with casters it must be installed with the casters supplied a connector complying with either ANSI Z21 69 CSA 6 16 and a quick...

Страница 8: ...allation 1 Unpack the flue box and flue wrap 2 Slide the flue box over the flue and secure it with the two self tapping screws using a 5 16 socket 3 Slide the flue wrap over the flue 4 Secure it with...

Страница 9: ...nd ventilation air is not obstructed Provisions for adequate air supply must also be provided Do NOT obstruct the bottom front of the unit as combustion air enters through this area Be sure to inspect...

Страница 10: ...combination gas valve and pressure regulator which is provided with each unit is set to maintain a 4 W C manifold pressure for natural gas or 10 0 W C manifold pressure for propane gas However to mai...

Страница 11: ...n is recommended for locating gas leaks Matches candle flame or other sources of ignition shall not be used for this purpose Check entire piping system including the internal piping and Pipe Union ins...

Страница 12: ...nob in this step 5 Do NOT turn the thermostat ON until the frypot is filled with oil or solid shortening 6 Once the frypot is filled with shortening set the thermostat to the desired temperature Pilot...

Страница 13: ...ot heat tubes RELIGHTING In the event of a main burner ignition failure a five minute purge period must be observed prior to re establishing the ignition source 1 Shut off all gas 2 Wait five minutes...

Страница 14: ...s on the amount and degree of usage Following daily and more extensive periodic maintenance procedures will increase the life of your equipment Climatic conditions e g salt air may result in the need...

Страница 15: ...h Dry thoroughly with a clean cloth Never use vinegar or any corrosive cleaner To remove grease and food splatter or condensed vapors that have baked on the equipment apply cleanser to a damp cloth or...

Страница 16: ...ain gas shutoff valve PARTS Installation of other then genuine parts will void the warranty on this equipment The serial plate is located inside the front door on the left side Replacement parts may b...

Страница 17: ...pane 302201337 Orifice Extension 3 4 5 14 302220073B Safety High Limit 450 F 1 1 1 15 302130202B Pilot 3 Way Natural 1 1 1 302130201B Pilot 3 Way Propane PARTS CONTINUED No Part Description F3 F4 F5 1...

Страница 18: ...013 Flue Wrap 1 1 20137058004 Flue Warp 1 No Part Description F3 F4 F5 1 20137056003 Door Assembly Complete 1 1 20137058003 Door Assembly Complete 1 302190245 Door Magnet 1 1 1 3 302090001 6 Adjustabl...

Страница 19: ...ged due to not being secured to the floor Products that have been modified abused or misused Any products that have been exposed to corrosive or other cleaners not intended for use on stainless steel...

Отзывы: