Step 10. Insert the last building elements by gently sliding them from above into the notches in the
frame of the building structure.
Step 11. After the installation of the unit and the installation, the cover must be broken out in place,
in which the chimney will be led out in order to freely lead the flue pipe.
SELECTION OF THE LOCATION OF THE DEVICE IN A DEDICATED BUILDING.
The choice of the place of installation of the device in a dedicated building should be dictated by the
location of the chimney to which it will be connected. Dedicated installation gives you several possi-
bilities of chimney exit depending on the conditions created by the existing chimney installation, or
depending on the final chimney exit method.
CONNECTION OF THE DEVICE TO THE CHIMNEY SYSTEM.
The connection of the fireplace to the chimney system must comply with local building regulations
and the guidelines contained in the appliance manual. If there are no local guidelines for the installa-
tion of the appliance and its chimney installation, follow the instructions in the appliance manual and
its connection to the purchased appliance.
MAINTENANCE / ATTENTION!!!
All maintenance work should be carried out on a cooled down unit at least 12 hours after it has
been extinguished.