![Kranzle HD 10/120 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/kranzle/hd-10-120/hd-10-120_operating-manual_2002518006.webp)
6
Electrical connection
The machine is supplied with an electrical power cable with plug.
The mains plug must be fitted to a standard grounded socket with a
30mA
residual current operated device. The socket must be protected
with a
16A
delay action fuse on the mains side.
KRÄNZLE HD 7/120 230 Volt / 50 Hz
KRÄNZLE HD 10/120 230 Volt / 50 Hz
When using an extension cable, this must have an earthed lead
which is properly connected to the socket. The conductors in the
extension cable must have a minimum cross section of 1.5 mm².
Plug connections must be of a spray-proof design, and may not
be located on a wet floor.
(with extension cables of more than 10 m - 2.5 mm
2
)
CAUTION !
The use of extension cables which are too long may lead to malfunctions and
start up difficulty.
When using a cable drum, always keep the cable wound as far as possible.
Description
230 V
Содержание HD 10/120
Страница 22: ...22 Complete assembly...
Страница 24: ...24 Motor...
Страница 26: ...26 Transmission...
Страница 28: ...28 Valve housing...
Страница 34: ...34 Notes...
Страница 35: ...35 Notes...
Страница 36: ...Reprint only allowed with the authorization of As date of 06 07 2005 Order n 30 760 1 R...